دورية أكاديمية

Estimating uncertainty of target values for DEQAS serum materials.

التفاصيل البيبلوغرافية
العنوان: Estimating uncertainty of target values for DEQAS serum materials.
المؤلفون: Durazo-Arvizu, Ramon, Ahmed, F., Berry, J., Cavalier, Etienne, Gunter, E., Jones, G., Jones, J., Sempos, C. T., Twomey, P. J., Williams, E. L., Carter, G. D.
المصدر: Journal of Steroid Biochemistry and Molecular Biology (2019)
بيانات النشر: Elsevier, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Human health sciences, Laboratory medicine & medical technology, Sciences de la santé humaine, Médecine de laboratoire & technologie médicale
الوصف: The External Quality Assessment (EQA) scheme for vitamin D metabolites (DEQAS) distributes human serum samples to laboratories across the world to assess their performance in measuring serum total 25-hydroxyvitamin D [25(OH)D], i.e. the sum of the concentrations of serum 25(OH)D2 and 25(OH)D3. In 2013 DEQAS, in collaboration with the Vitamin D Standardization Program (VDSP), became an accuracy-based EQAS when the National Institute for Standards and Technology (NIST) began assigning 25(OH)D target values to DEQAS serum samples using their Joint Committee for Traceability in Laboratory Medicine (JCTLM) approved reference measurement procedure (RMP). Historically, NIST has performed 4 determinations of 25-OHD2 and 25-OHD3 on each sample and used the mean values to calculate a single 'target value' for Total 25-OHD against which performance was judged. By definition the target values cannot be exact and each is associated with a level of uncertainty. The total uncertainty (UNIST) has two components, one from the 25(OH)D2, and 25(OH)D3 measurements and the other associated with the calibration procedure. The total combined uncertainty is calculated by adding up these uncertainties. In future, uncertainties will be attached to the target value in each DEQAS serum sample, starting with the next distribution cycle in 2019. Confidence intervals obtained using these uncertainties will allow DEQAS participants to determine if their result agrees with the NIST assigned target value. Furthermore, if the value falls within the confidence interval the laboratory's assay would be regarded as traceable, i.e. standardized, to the NIST RMP.
نوع الوثيقة: journal article
http://purl.org/coar/resource_type/c_6501Test
article
اللغة: English
العلاقة: urn:issn:0960-0760; urn:issn:1879-1220
DOI: 10.1016/j.jsbmb.2018.12.011
الوصول الحر: https://orbi.uliege.be/handle/2268/232156Test
حقوق: restricted access
http://purl.org/coar/access_right/c_16ecTest
info:eu-repo/semantics/restrictedAccess
رقم الانضمام: edsorb.232156
قاعدة البيانات: ORBi