دورية أكاديمية

Exposed Subcutaneous Implantable Devices: An Operative Protocol for Management and Salvage

التفاصيل البيبلوغرافية
العنوان: Exposed Subcutaneous Implantable Devices: An Operative Protocol for Management and Salvage
المؤلفون: Francesca Toia, MD, Salvatore D’Arpa, MD, PhD, Adriana Cordova, MD, Francesco Moschella, MD
المصدر: Plastic and Reconstructive Surgery, Global Open, Vol 3, Iss 3S-1, Supplement 2014 SICPRE Congress Best Abstracts, p e343 (2015)
بيانات النشر: Wolters Kluwer, 2015.
سنة النشر: 2015
المجموعة: LCC:Surgery
مصطلحات موضوعية: Surgery, RD1-811
الوصف: Background: Implantable venous and electrical devices are prone to exposure and infection. Indications for management are controversial, but—especially if infected—exposed devices are often removed and an additional operation is needed to replace the device, causing a delay in chemotherapy and prolonging healing time. We present our protocol for device salvage, on which limited literature is available. Methods: Between 2007 and 2013, 17 patients were treated (12 venous access ports, 3 cardiac pacemakers, and 2 subcutaneous neural stimulators). Most patients were operated within 7 days from exposure. All patients received only a single perioperative dose of prophylactic antibiotic. In cases of gross infection (n = 1), the device was immediately replaced. In the absence of clinical signs of infection: Complete capsulectomy and aggressive cleaning with an n-acetylcysteine solution and saline solution. Primary exposure of venous ports with sufficient skin coverage (n = 10): the device was covered with local skin flaps. Recurrent cases, cases with insufficient skin coverage or big devices (n = 7): the device was moved to a subpectoral pocket. Mean follow-up was 19 months. Results: Sixteen devices were saved. Only one grossly infected pacemaker was removed and replaced immediately. Only in 1 case, exposure of a venous port recurred after 18 months and was successfully moved to a subpectoral pocket. Chemotherapy was always restarted as scheduled and electrical devices remained functional. Conclusions: This protocol allows—with a straightforward operation and simple measures—to save exposed devices even several days after exposure. Submuscular placement or immediate replacement is indicated only in selected cases.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2169-7574
العلاقة: http://journals.lww.com/prsgo/Fulltext/2015/03001/Article.7.aspxTest; https://doaj.org/toc/2169-7574Test
DOI: 10.1097/01.GOX.0000464837.59870.6f
الوصول الحر: https://doaj.org/article/b9468baba0c94b66a2b8b71dfed58fbeTest
رقم الانضمام: edsdoj.b9468baba0c94b66a2b8b71dfed58fbe
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21697574
DOI:10.1097/01.GOX.0000464837.59870.6f