دورية أكاديمية

Effect of the Adhesive Strategy on Clinical Performance and Marginal Integrity of a Universal Adhesive in Non-Carious Cervical Lesions in a Randomized 36-Month Study

التفاصيل البيبلوغرافية
العنوان: Effect of the Adhesive Strategy on Clinical Performance and Marginal Integrity of a Universal Adhesive in Non-Carious Cervical Lesions in a Randomized 36-Month Study
المؤلفون: Rainer Haak, Gesa Stache, Hartmut Schneider, Matthias Häfer, Gerhard Schmalz, Ellen Schulz-Kornas
المصدر: Journal of Clinical Medicine, Vol 12, Iss 18, p 5776 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Medicine
مصطلحات موضوعية: application mode, universal adhesive, non-carious cervical lesion, randomized clinical trial, FDI criteria, quantitative margin analysis, Medicine
الوصف: The effectiveness of a universal adhesive applied in three application modes for the preparation of Class V composite restorations was evaluated both clinically and by quantitative marginal analysis (QMA) over 36 months. In 50 patients, three (n = 21) or four (n = 29) non-carious cervical lesions (NCCL) were restored with Venus® Diamond Flow (Kulzer GmbH, Hanau, Germany). The adhesive iBond® Universal (iBU, Kulzer, Germany) was used in self-etch (SE), etch-and-rinse (ER), or selective-enamel-etch mode (SEE). The etch-and-rinse adhesive OptiBondTM FL served as a control (OFL, Kerr GmbH, Herzogenrath, Germany). The restorations were clinically assessed (FDI criteria) at 14 days (BL), 6, 12, 24, and 36 months. Additionally, QMA was conducted on all restorations of 11 randomly selected patients. FDI criteria and marginal gap and perfect margin were compared between and within groups and recalls using McNemar, Wilcoxon, or Mann–Whitney U-tests (α = 0.05). Starting with 12 months, cumulative failure rates were lower in iBU-SE (0.0%, p = 0.016) and iBU-ER groups (2.1%, p = 0.07) compared to OFL (16.7%). At two years, iBU-SEE also showed fewer failures (0.0% SEE vs. 34.6% OFL, p = 0.016), as did iBU-SE compared to iBU-ER after 36 months (2.2 and 19.6%, p = 0.039). From BL, the iBU-SEE group always had the fewest marginal gaps and the highest percentage of perfect margins. From BL, iBU-SEE (0%, p = 0.008) and iBU-ER (0.2%, p = 0.027) showed significantly fewer marginal gaps compared to OFL (2.5%) and more perfect margins were found with iBU-SEE starting at 6 months (p = 0.054). The SEE and ER modes ensured the most excellent marginal quality, with differences from the control appearing earlier with QMA than clinically. In restoring NCCls, iBU showed superior clinical performance over OFL, especially in modes SE and SEE.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0383
العلاقة: https://www.mdpi.com/2077-0383/12/18/5776Test; https://doaj.org/toc/2077-0383Test
DOI: 10.3390/jcm12185776
الوصول الحر: https://doaj.org/article/9d62185c20d34a37b573d4af353a54e7Test
رقم الانضمام: edsdoj.9d62185c20d34a37b573d4af353a54e7
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770383
DOI:10.3390/jcm12185776