Evaluation of dose delivery based on deformed CT using a commercial software for lung cancer

التفاصيل البيبلوغرافية
العنوان: Evaluation of dose delivery based on deformed CT using a commercial software for lung cancer
المؤلفون: Jihong Chen, Kaiqiang Chen, Min OuYang, Guohua Wang, Penggang Bai, Hongqiang You
المصدر: Scientific Reports, Vol 14, Iss 1, Pp 1-8 (2024)
بيانات النشر: Nature Portfolio, 2024.
سنة النشر: 2024
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Deformable image registration, Lung cancer, CBCT, Adaptive radiotherapy, Medicine, Science
الوصف: Abstract This study employed a commercial software velocity to perform deformable registration and dose calculation on deformed CT images, aiming to assess the accuracy of dose delivery during the radiotherapy for lung cancers. A total of 20 patients with lung cancer were enrolled in this study. Adaptive CT (ACT) was generated by deformed the planning CT (pCT) to the CBCT of initial radiotherapy fraction, followed by contour propagation and dose recalculation. There was not significant difference between volumes of GTV and CTV calculated from the ACT and pCT. However, significant differences in dice similarity coefficient (DSC) and coverage ratio (CR) between GTV and CTV were observed, with lower values for GTV volumes below 15 cc. The mean differences in dose corresponding to 95% of the GTV, GTV-P, CTV, and CTV-P between ACT and pCT were − 0.32%, 4.52%, 2.17%, and 4.71%, respectively. For the dose corresponding to 99%, the discrepancies were − 0.18%, 8.35%, 1.92%, and 24.96%, respectively. These differences in dose primarily appeared at the edges of the target areas. Notably, a significant enhancement of dose corresponding to 1 cc for spinal cord was observed in ACT, compared with pCT. There was no statistical difference in the mean dose of lungs and heart. In general, for lung cancer patients, anatomical motion may result in both CTV and GTV moving outside the original irradiation region. The dose difference within the original target area was small, but the difference in the planning target area was considerable.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2045-2322
العلاقة: https://doaj.org/toc/2045-2322Test
DOI: 10.1038/s41598-024-65381-x
الوصول الحر: https://doaj.org/article/9b77d6315637417fa46ece2674406c7bTest
رقم الانضمام: edsdoj.9b77d6315637417fa46ece2674406c7b
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20452322
DOI:10.1038/s41598-024-65381-x