دورية أكاديمية

Unilateral C1 Posterior Arch Screw-C2 Laminar Screw Posterior Fixation for Vertebral Artery Preservation in Bow Hunter’s Syndrome

التفاصيل البيبلوغرافية
العنوان: Unilateral C1 Posterior Arch Screw-C2 Laminar Screw Posterior Fixation for Vertebral Artery Preservation in Bow Hunter’s Syndrome
المؤلفون: Tatsuya Tanaka, Ren Fujiwara, Haruki Funao, Shigeto Ebata, Ryohei Sashida, Yu Hirokawa, Tomihiro Wakamiya, Yuhei Michiwaki, Kazuaki Shimoji, Eiichi Suehiro, Keisuke Onoda, Fumitaka Yamane, Ken Ishii, Masatou Kawashima, Akira Matsuno
المصدر: Case Reports in Neurology, Vol 14, Iss 3, Pp 469-474 (2022)
بيانات النشر: Karger Publishers, 2022.
سنة النشر: 2022
المجموعة: LCC:Neurology. Diseases of the nervous system
مصطلحات موضوعية: posterior arch screw, vertebral artery injury, bow hunter’s syndrome, posterior fixation, complications, Neurology. Diseases of the nervous system, RC346-429
الوصف: Pedicle or lateral mass screws, which are usually used to fix atlantoaxial instability, increase the risk of vertebral artery (VA) injury in patients with bone or arterial anomalies or osteoporotic bone. Here, we report the use of a unilateral C1 posterior arch screw-C2 laminar screw posterior fixation with a contralateral C1 lateral mass screw for VA preservation in a patient with bow hunter’s syndrome (BHS). A 65-year-old male presented with recurrent loss of consciousness in the right rotational and backward-bending head positions for 1 year. Cerebral angiography in the same head position showed that the left VA was disrupted at C1/2 and the right VA was hypoplastic. The patient was diagnosed with BHS. C1-2 posterior fixation and iliac bone grafting were performed. The left VA was on the dominant side, and the VA was in a high position; thus, a C1 posterior arch screw was selected for the left side, a C1 lateral mass screw was selected for the right side, and a C2 laminar screw with O-arm navigation and a C-arm was used to prevent arterial injury. Intraoperative findings revealed no VA injury, and postoperative computed tomography showed the screw at the planned site. In a patient with BHS, posterior fixation with a unilateral C1 posterior arch screw-C2 laminar screw prevented VA injury because the screw could be inserted while avoiding the VA.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1662-680X
العلاقة: https://www.karger.com/Article/FullText/528058Test; https://doaj.org/toc/1662-680XTest
DOI: 10.1159/000528058
الوصول الحر: https://doaj.org/article/c9624b53306f4324b9e40491ac5880d1Test
رقم الانضمام: edsdoj.9624b53306f4324b9e40491ac5880d1
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1662680X
DOI:10.1159/000528058