Accuracy of patient-specific I-131 dosimetry using hybrid whole-body planar-SPECT/CT I-123 and I-131 imaging

التفاصيل البيبلوغرافية
العنوان: Accuracy of patient-specific I-131 dosimetry using hybrid whole-body planar-SPECT/CT I-123 and I-131 imaging
المؤلفون: Michaella Morphis, Johan A. van Staden, Hanlie du Raan, Michael Ljungberg, Katarina Sjögreen Gleisner
المصدر: EJNMMI Physics, Vol 11, Iss 1, Pp 1-18 (2024)
بيانات النشر: SpringerOpen, 2024.
سنة النشر: 2024
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: Monte Carlo simulations, SIMIND, Hybrid whole-body planar-SPECT/CT, 123I, 131I, mIBG, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Abstract Purpose This study aimed to assess the accuracy of patient-specific absorbed dose calculations for tumours and organs at risk in radiopharmaceutical therapy planning, utilizing hybrid planar-SPECT/CT imaging. Methods Three Monte Carlo (MC) simulated digital patient phantoms were created, with time-activity data for mIBG labelled to I-123 (LEHR and ME collimators) and I-131 (HE collimator). The study assessed the accuracy of the mean absorbed doses for I-131-mIBG therapy treatment planning. Multiple planar whole-body (WB) images were simulated (between 1 to 72 h post-injection (p.i)). The geometric-mean image of the anterior and posterior WB images was calculated, with scatter and attenuation corrections applied. Time-activity curves were created for regions of interest over the liver and two tumours (diameters: 3.0 cm and 5.0 cm) in the WB images. A corresponding SPECT study was simulated at 24 h p.i and reconstructed using the OS-EM algorithm, incorporating scatter, attenuation, collimator-detector response, septal scatter and penetration corrections. MC voxel-based absorbed dose rate calculations used two image sets, (i) the activity distribution represented by the SPECT images and (ii) the activity distribution from the SPECT images distributed uniformly within the volume of interest. Mean absorbed doses were calculated considering photon and charged particle emissions, and beta emissions only. True absorbed doses were calculated by MC voxel-based dosimetry of the known activity distributions for reference. Results Considering photon and charged particle emissions, mean absorbed dose accuracies across all three radionuclide-collimator combinations of 3.8 ± 5.5% and 0.1 ± 0.9% (liver), 5.2 ± 10.0% and 4.3 ± 1.7% (3.0 cm tumour) and 15.0 ± 5.8% and 2.6 ± 0.6% (5.0 cm tumour) were obtained for image set (i) and (ii) respectively. Considering charged particle emissions, accuracies of 2.7 ± 4.1% and 5.7 ± 0.7% (liver), 3.2 ± 10.2% and 9.1 ± 1.7% (3.0 cm tumour) and 13.6 ± 5.7% and 7.0 ± 0.6% (5.0 cm tumour) were obtained for image set (i) and (ii) respectively. Conclusion The hybrid WB planar-SPECT/CT method proved accurate for I-131-mIBG dosimetry, suggesting its potential for personalized treatment planning.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2197-7364
العلاقة: https://doaj.org/toc/2197-7364Test
DOI: 10.1186/s40658-024-00657-9
الوصول الحر: https://doaj.org/article/8e2f81af11314e429f107379caa6f057Test
رقم الانضمام: edsdoj.8e2f81af11314e429f107379caa6f057
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21977364
DOI:10.1186/s40658-024-00657-9