دورية أكاديمية

Influence of moderate prosthesis–patient mismatch on long-term outcomes in patients with severe aortic stenosis with paradoxically reduced gradients against the background of reduced stroke volume after aortic valve replacement with a biological prosthesis: retrospective comparative study

التفاصيل البيبلوغرافية
العنوان: Influence of moderate prosthesis–patient mismatch on long-term outcomes in patients with severe aortic stenosis with paradoxically reduced gradients against the background of reduced stroke volume after aortic valve replacement with a biological prosthesis: retrospective comparative study
المؤلفون: Vladlen V. Bazylev, Ruslan M. Babukov, Fedor L. Bartosh, Alena V. Levina
المصدر: КардиоСоматика, Vol 14, Iss 3, Pp 143-154 (2023)
بيانات النشر: Concilium Medicum, 2023.
سنة النشر: 2023
المجموعة: LCC:Diseases of the circulatory (Cardiovascular) system
LCC:Diseases of the endocrine glands. Clinical endocrinology
مصطلحات موضوعية: aortic stenosis, patient–prosthesis mismatch, biological prosthesis, paradoxically low stroke volume, low gradients, Diseases of the circulatory (Cardiovascular) system, RC666-701, Diseases of the endocrine glands. Clinical endocrinology, RC648-665
الوصف: OBJECTIVE: Our aim was to evaluate the impact of moderate prosthesis–patient mismatch on long-term results after aortic valve replacement in patients with severe aortic stenosis with paradoxically reduced gradients against the background of a reduced stroke volume of the left ventricle. MATERIALS AND METHODS: We analyzed data from 88 patients with symptomatic severe aortic stenosis meeting the criteria: paradoxically reduced gradients against the background of a reduced stroke volume of the left ventricle. Patients were divided into 2 groups: Group 1 (n=42, mean age 67±4 years) with paradoxically reduced gradients against the background of reduced stroke volume of the left ventricle, with a moderate patient–prosthesis mismatch; Group 2 (n=46, mean age 68±6 years) with paradoxically reduced gradients against the background of reduced stroke volume of the left ventricle, without patient–prosthesis discrepancy. All patients underwent transthoracic echocardiographic evaluation. RESULTS: The average follow-up period was 84 (quarterly interval 75±98) months, during the follow-up period 35 (40%) deaths were registered. There were no significant differences in in-hospital mortality: 2 (4.7%) and 2 (4.3%), respectively (p=0.2). In the long-term follow-up period, there was a significant difference in survival and hospitalization rates for exacerbation of heart failure between patients with and without patient–prosthesis mismatch: 46 and 71%, 37 and 72%, respectively (p0.001). In the long-term follow-up period, patients with patient–prosthesis mismatch showed a trend towards slower regression of left ventricle mass and left atrial volume, as well as a slower recovery of global longitudinal deformation of the left ventricle and exercise tolerance compared with patients without patient–prosthesis mismatch. There were no significant differences in the incidence of stroke (90% and 91%; p=0.7). According to the results of Cox regression, the left ventricular stroke volume index and the aortic valve effective orifice area index were independent predictors of lethal events and the risk of hospitalization for exacerbation of heart failure. CONCLUSION: Moderate patient–prosthesis mismatch in patients with paradoxically reduced gradients associated with reduced left ventricular stroke volume is independently associated with increased mortality and increased hospitalization for exacerbations of heart failure.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Russian
تدمد: 2221-7185
2658-5707
العلاقة: https://cardiosomatics.ru/2221-7185/article/viewFile/340856/pdf_1Test; https://doaj.org/toc/2221-7185Test; https://doaj.org/toc/2658-5707Test
DOI: 10.17816/CS340856
الوصول الحر: https://doaj.org/article/7c4ace33631443e581ff7e281232eec6Test
رقم الانضمام: edsdoj.7c4ace33631443e581ff7e281232eec6
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22217185
26585707
DOI:10.17816/CS340856