Performance Assessment of Two Different Approaches of Measuring Skeletonized Radial Peripapillary Capillary Vessel Density in Glaucoma Patients

التفاصيل البيبلوغرافية
العنوان: Performance Assessment of Two Different Approaches of Measuring Skeletonized Radial Peripapillary Capillary Vessel Density in Glaucoma Patients
المؤلفون: Yiqin Guo, Yunxiao Sun, Xueyuan Zhang, Ningli Wang
المصدر: Frontiers in Medicine, Vol 8 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: measuring method, OCT angiography, glaucoma, radial peripapillary capillary vessel density, skeletonization, Medicine (General), R5-920
الوصف: ObjectiveTo compare performance assessment of two methods of measuring radial peripapillary capillary (RPC) vessel density (VD) after skeletonization using MATLAB and Image J in glaucoma clinical setting.MethodsSeventy-three eyes of 73 glaucoma patients from Beijing Tongren Hospital were included in this prospective study. Original images of RPC were obtained using optical coherence tomography angiography. Two approaches were executed before measuring. Method 1 (M1) required image sharpening, removal of big vessels, and skeletonization. Method 2 (M2) required skeletonization and removal of major vessels. Each method was executed twice. Repeatability and correlations with glaucomatous parameters were assessed. Factors associated with retinal nerve fiber layer thickness (RNFLT) and visual field mean deviation (MD) were analyzed.ResultsAverage VD was 13.86 ± 2.73 and 7.50 ± 2.50% measured by M1 and M2. Percentage of total elimination of the major vessels was 36.99 and 100% by M1 and M2, respectively. The intrasession and intersession reproducibility was higher by M2 (ICC = 0.979, ICC = 0.990) than by M1 (ICC = 0.930, ICC = 0.934). VD measured by M2 showed stronger correlations with glaucomatous parameters than by M1. By stepwise multiple linear regression, thinner RNFLT was associated with smaller VD measured by M2 (B = 4.643, P < 0.001). Worse MD was associated with smaller VD measured by M1 (B = 1.079, P = 0.015).ConclusionThe VD measured by M2 showed better reproducibility and higher correlation with glaucomatous structural parameters. Image sharpning helps display of hazy vasculature in glaucoma, which may reflect visual function better. Researchers should carefully choose image processing methods according to their research object.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2296-858X
العلاقة: https://www.frontiersin.org/articles/10.3389/fmed.2021.814306/fullTest; https://doaj.org/toc/2296-858XTest
DOI: 10.3389/fmed.2021.814306
الوصول الحر: https://doaj.org/article/6dae2c9069c14699865f8ed61de690d1Test
رقم الانضمام: edsdoj.6dae2c9069c14699865f8ed61de690d1
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2296858X
DOI:10.3389/fmed.2021.814306