Long-term efficacy of sensor-augmented pump therapy (Minimed 640G system) combined with a telemedicine follow-up in patients with type 1 diabetes: A real life study
التفاصيل البيبلوغرافية
العنوان:
Long-term efficacy of sensor-augmented pump therapy (Minimed 640G system) combined with a telemedicine follow-up in patients with type 1 diabetes: A real life study
Objective: Evaluate the efficacy of a new modality of insulin therapy associating both the sensor-augmented pump therapy with predictive low-glucose management (SAP-PLGM) and a telemedicine follow-up in patients with Type 1 diabetes (T1D) in a real-life setting. Methods: T1D adults under Minimed 640G system with a telemedicine follow-up for glucose management were included in a retrospective study. The primary endpoint was HbA1c while continuous glucose monitoring parameters (CGM) and treatment compliance were the secondary endpoints. These parameters were analyzed according to the therapeutic indication, HbA1c ≥ 8 % (Group A) or severe hypoglycemic events (Group B) and in patients switched to SAP-PLGM therapy. Results: 62 patients were analyzed with a 28 ± 12 months of follow-up. In Group A, HbA1c decreased from 8.3 ± 0.4 % to 7.7 ± 0.7 % (p