دورية أكاديمية

Flow Diverter in Unruptured Intracranial Vertebral Artery Dissecting Aneurysm

التفاصيل البيبلوغرافية
العنوان: Flow Diverter in Unruptured Intracranial Vertebral Artery Dissecting Aneurysm
المؤلفون: Han San Oh, Jin Woo Bae, Chang-eui Hong, Kang Min Kim, Dong Hyun Yoo, Hyun-Seung Kang, Young Dae Cho
المصدر: Frontiers in Neurology, Vol 13 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Neurology. Diseases of the nervous system
مصطلحات موضوعية: aneurysm, vertebral artery, dissection, reconstructive, flow diverter, Neurology. Diseases of the nervous system, RC346-429
الوصف: ObjectiveIntracranial vertebral artery dissecting aneurysm (VADA) may present as aneurysmal dilation alone, dilation with coexisting stenosis, or, in some cases, as a recurrent aneurysm after previous reconstructive treatment. To date, the clinical utility of flow diverters in VADA has not been examined according to these various circumstances. This study aims to report the safety and efficacy of flow diverters in the treatment of various manifestations of intracranial VADA.MethodsA total of 26 patients and 27 VADAs treated with flow diverting stents from November 2014 to September 2021 were included. Medical records and radiologic data were analyzed to assess the safety and efficacy of flow diverting stents.ResultsThe results showed that 12 cases (44.4%) presented with aneurysmal dilation only, 7 (26.0%) with aneurysmal dilation and one or more associated stenotic lesions, and 8 (29.6%) as recurrence after previous treatment, including stent-assisted coil embolization (n = 5), single stent only (n = 1), and coil embolization without stent (n = 2). Among 27 lesions, 25 were treated with single flow diverters; additional flow diverting stents were required in 2 cases because of incomplete coverage of the aneurysm neck. There was one instance of incomplete expansion of the flow diverter. All cases showed contrast stagnation in the aneurysmal sac immediately after deployment of the flow diverting stent, and during a mean follow-up period of 18.6 months (range 6 to 60), the overall complete occlusion rate was 55.6%, with complete occlusion of 83.3% of aneurysmal dilation only lesions, 42.9% of aneurysms with stenosis, and 25% of the recurrent aneurysm. Only two patients (7.7%) had delayed ischemic complications.ConclusionFlow diverters have proven safe and effective in unruptured VADA. However, the complete occlusion rate with the flow diverter is relatively lower in VADA with stenosis or with previous stent placement than in dilation-only lesions. Further study with a larger cohort would be needed to confirm these results.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1664-2295
العلاقة: https://www.frontiersin.org/articles/10.3389/fneur.2022.912863/fullTest; https://doaj.org/toc/1664-2295Test
DOI: 10.3389/fneur.2022.912863
الوصول الحر: https://doaj.org/article/d4f957479cd347ef95b775984d69b2deTest
رقم الانضمام: edsdoj.4f957479cd347ef95b775984d69b2de
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16642295
DOI:10.3389/fneur.2022.912863