دورية أكاديمية

Comparison of conventional immunochromatographic assay with new automated-Treponema pallidum hemagglutination assay for screening of syphilis in blood donors

التفاصيل البيبلوغرافية
العنوان: Comparison of conventional immunochromatographic assay with new automated-Treponema pallidum hemagglutination assay for screening of syphilis in blood donors
المؤلفون: Devi Prasad Acharya, Aseem K Tiwari, Geet Aggarwal, Dinesh Arora, Ravi C Dara, Gunjan Bhardwaj, Gautam Kumar Gupta
المصدر: Global Journal of Transfusion Medicine, Vol 4, Iss 2, Pp 191-197 (2019)
بيانات النشر: Wolters Kluwer Medknow Publications, 2019.
سنة النشر: 2019
المجموعة: LCC:Diseases of the blood and blood-forming organs
مصطلحات موضوعية: automated treponema pallidum hemagglutination assay, fluorescent treponemal antibody-absorption assay, immunochromatographic assay, rapid plasma reagin, serological test for syphilis, syphilis, Diseases of the blood and blood-forming organs, RC633-647.5
الوصف: Introduction: Serological tests for syphilis contributed greatly to the detection of Treponema pallidum infection in blood donors and especially in those who were missed during the medical selection. Although several different treponemal assays have been evaluated in India, the debate that which treponemal test-formats would be suitable for a particular blood transfusion service is far from settled. Aims and Objectives: The study was undertaken with an objective of comparing conventional immunochromatographic assay (ICA) with new automated T. pallidum hemagglutination assay (a-TPHA) in over 10,000 consecutive blood donor samples with fluorescent treponemal antibody-absorption assay (FTA-Abs) as the gold standard to resolve the discordant samples. Materials and Methods: The study was conducted in the Department of Transfusion Medicine in a large tertiary care hospital in India. Consecutive blood donors from July 2014 to January 2015 were evaluated simultaneously for antitreponemal antibodies by solid-phase ICA (SD BIOLINE Syphilis 3.0, Alere Medical Pvt. Ltd., USA), a-TPHA (Immucor Diagnostics, USA) and FTA-Abs (Biocientifica SA, FTA-Abs, Argentina). Performances of both the assays were evaluated using statistical tools. Results: A total of 10,129 donor samples were evaluated. A total of 113 (1.1%) donor samples were reactive for syphilis; either on ICA or a-TPHA or both. Ninety-one of these 113 reactive samples were reactive on FTA-Abs, giving seroprevalance of syphilis as 0.9%. a-TPHA was superior to ICA in terms of sensitivity, specificity, positive predictive value, negative predictive value, and Youden's index. Conclusion: The new “a-TPHA” is a superior assay to ICA as the screening assay for syphilis in blood donors.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2468-8398
2455-8893
العلاقة: http://www.gjtmonline.com/article.asp?issn=2468-8398;year=2019;volume=4;issue=2;spage=191;epage=197;aulastTest=; https://doaj.org/toc/2468-8398Test; https://doaj.org/toc/2455-8893Test
DOI: 10.4103/GJTM.GJTM_55_19
الوصول الحر: https://doaj.org/article/4f4c61016dd6462ca5ca3d39fca5c2ebTest
رقم الانضمام: edsdoj.4f4c61016dd6462ca5ca3d39fca5c2eb
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:24688398
24558893
DOI:10.4103/GJTM.GJTM_55_19