دورية أكاديمية

Occurrence of pendelluft under pressure support ventilation in patients who failed a spontaneous breathing trial: an observational study

التفاصيل البيبلوغرافية
العنوان: Occurrence of pendelluft under pressure support ventilation in patients who failed a spontaneous breathing trial: an observational study
المؤلفون: Andrea Coppadoro, Alice Grassi, Cecilia Giovannoni, Francesca Rabboni, Nilde Eronia, Alfio Bronco, Giuseppe Foti, Roberto Fumagalli, Giacomo Bellani
المصدر: Annals of Intensive Care, Vol 10, Iss 1, Pp 1-10 (2020)
بيانات النشر: SpringerOpen, 2020.
سنة النشر: 2020
المجموعة: LCC:Medical emergencies. Critical care. Intensive care. First aid
مصطلحات موضوعية: Pendelluft, Electrical impedance tomography, Difficult ventilator weaning, Assisted mechanical ventilation, Spontaneous assisted breathing, Spontaneous breathing trial, Medical emergencies. Critical care. Intensive care. First aid, RC86-88.9
الوصف: Abstract Background Pendelluft, the movement of gas within different lung regions, is present in animal models of assisted mechanical ventilation and associated with lung overstretching. Due to rebreathing of CO2 as compared to fresh gas, pendelluft might reduce ventilatory efficiency possibly exacerbating patient’s respiratory workload during weaning. Our aim was to measure pendelluft by electrical impedance tomography (EIT) in patients who failed a spontaneous breathing trial (SBT). Methods This is an observational study conducted in a general intensive care unit of a tertiary-level teaching hospital. EIT signal was recorded in 20 patients while pressure support (PS) ventilation was progressively reduced from clinical level (baseline) to 2 cmH2O, as in an SBT; four ventral-to-dorsal lung regions of interest were identified for pendelluft measurement. A regional gas movement (> 6 mL) occurring in a direction opposite to the global EIT signal was considered diagnostic for high pendelluft. Results Eight patients out of 20 (40%) were classified as high-pendelluft; baseline clinical characteristics did not differ between high- and low-pendelluft patients. At PS reduction, pendelluft and EtCO2 increased more in the high-pendelluft group (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2110-5820
العلاقة: http://link.springer.com/article/10.1186/s13613-020-00654-yTest; https://doaj.org/toc/2110-5820Test
DOI: 10.1186/s13613-020-00654-y
الوصول الحر: https://doaj.org/article/436ed4a53d5342d7b2cc6e781d8c2d9dTest
رقم الانضمام: edsdoj.436ed4a53d5342d7b2cc6e781d8c2d9d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21105820
DOI:10.1186/s13613-020-00654-y