دورية أكاديمية

The effect of imaging modality (magnetic resonance imaging vs. computed tomography) and patient position (supine vs. prone) on target and organ at risk doses in partial breast irradiation

التفاصيل البيبلوغرافية
العنوان: The effect of imaging modality (magnetic resonance imaging vs. computed tomography) and patient position (supine vs. prone) on target and organ at risk doses in partial breast irradiation
المؤلفون: Emily Brown, Kylie Dundas, Yolanda Surjan, Daniela Miller, Karen Lim, Miriam Boxer, Verity Ahern, George Papadatos, Vikneswary Batumalai, Jennifer Harvey, Debra Lee, Geoff P. Delaney, Lois Holloway
المصدر: Journal of Medical Radiation Sciences, Vol 68, Iss 2, Pp 157-166 (2021)
بيانات النشر: Wiley, 2021.
سنة النشر: 2021
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: Magnetic resonance imaging, organs at risk, partial breast irradiation, patient positioning, X‐ray computed tomography, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Abstract Introduction Conventionally computed tomography (CT) has been used to delineate target volumes in radiotherapy; however, magnetic resonance imaging (MRI) is being continually integrated into clinical practice; therefore, the investigation into targets derived from MRI is warranted. The purpose of this study was to evaluate the impact of imaging modality (MRI vs. CT) and patient positioning (supine vs. prone) on planning target volumes (PTVs) and organs at risk (OARs) for partial breast irradiation (PBI). Methods A retrospective data set, of 35 patients, was accessed where each patient had undergone MRI and CT imaging for tangential whole breast radiotherapy in both the supine and prone position. PTVs were defined from seroma cavity (SC) volumes delineated on each respective image, resulting in 4 PTVs per patient. PBI plans were generated with 6MV external beam radiotherapy (EBRT) using the TROG 06.02 protocol guidelines. A prescription of 38.5Gy in 10 fractions was used for all cases. The impact analysis of imaging modality and patient positioning included dose to PTVs, and OARs based on agreed criteria. Statistical analysis was conducted though Mann–Whitey U, Fisher’s exact and chi‐squared testing (P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2051-3909
2051-3895
العلاقة: https://doaj.org/toc/2051-3895Test; https://doaj.org/toc/2051-3909Test
DOI: 10.1002/jmrs.453
الوصول الحر: https://doaj.org/article/3a59135dd3764e29a6ca2619091ce3aeTest
رقم الانضمام: edsdoj.3a59135dd3764e29a6ca2619091ce3ae
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20513909
20513895
DOI:10.1002/jmrs.453