دورية أكاديمية

External urethral sphincter pressure measurement: an accurate method for the diagnosis of detrusor external sphincter dyssynergia?

التفاصيل البيبلوغرافية
العنوان: External urethral sphincter pressure measurement: an accurate method for the diagnosis of detrusor external sphincter dyssynergia?
المؤلفون: Carlos H Suzuki Bellucci, Jens Wöllner, Flavia Gregorini, Dorothee Birnböck, Marko Kozomara, Ulrich Mehnert, Thomas M Kessler
المصدر: PLoS ONE, Vol 7, Iss 5, p e37996 (2012)
بيانات النشر: Public Library of Science (PLoS), 2012.
سنة النشر: 2012
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Medicine, Science
الوصف: Combined pelvic floor electromyography (EMG) and videocystourethrography (VCUG) during urodynamic investigation are the most acceptable and widely agreed methods for diagnosing detrusor external sphincter dyssynergia (DESD). Theoretically, external urethral sphincter pressure (EUSP) measurement would provide enough information for the diagnosis of DESD and could simplify the urodynamic investigation replacing combined pelvic floor EMG and VCUG. Thus, we evaluated the diagnostic accuracy of EUSP measurement for DESD. PATIENTS #ENTITYSTARTX00026;A consecutive series of 72 patients (36 women, 36 men) with neurogenic lower urinary tract dysfunction able to void spontaneously was prospectively evaluated at a single university spinal cord injury center. Diagnosis of DESD using EUSP measurement (index test) versus combined pelvic floor EMG and VCUG (reference standard) was assessed according to the recommendations of the Standards for Reporting of Diagnostic Accuracy Initiative.Using EUSP measurement (index test) and combined pelvic floor EMG and VCUR (reference standard), DESD was diagnosed in 10 (14%) and in 41 (57%) patients, respectively. More than half of the patients presented discordant diagnosis between the index test and the reference standard. Among 41 patients with DESD diagnosed by combined pelvic floor EMG and VCUR, EUSP measurement identified only 6 patients. EUSP measurement had a sensitivity of 15% (95% CI 5%-25%), specificity of 87% (95% CI 76%-98%), positive predictive value of 60% (95% CI 30%-90%), and negative predictive value of 56% (95% CI 44%-68%) for the diagnosis of DESD.For diagnosis of DESD, EUSP measurement is inaccurate and cannot replace combined pelvic floor EMG and VCUR.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1932-6203
العلاقة: http://europepmc.org/articles/PMC3365101?pdf=renderTest; https://doaj.org/toc/1932-6203Test
DOI: 10.1371/journal.pone.0037996
الوصول الحر: https://doaj.org/article/1e462b37950b491dbfde880893f587d2Test
رقم الانضمام: edsdoj.1e462b37950b491dbfde880893f587d2
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0037996