العنوان: A fully artificial pancreas versus a hybrid artificial pancreas for type 1 diabetes: a single-centre, open-label, randomised controlled, crossover, non-inferiority trial
المؤلفون: Michael A Tsoukas, MD, Dorsa Majdpour, Meng, Jean-François Yale, MD, Anas El Fathi, PhD, Natasha Garfield, MD, Joanna Rutkowski, Eng, Jennifer Rene, RN, Laurent Legault, MD, Ahmad Haidar, PhD
المصدر: The Lancet: Digital Health, Vol 3, Iss 11, Pp e723-e732 (2021)
بيانات النشر: Elsevier, 2021.
سنة النشر: 2021
المجموعة: LCC:Computer applications to medicine. Medical informatics
مصطلحات موضوعية: Computer applications to medicine. Medical informatics, R858-859.7
الوصف: Summary: Background: For people with type 1 diabetes, there is currently no automated insulin delivery system that does not require meal input. We aimed to assess the efficacy of a novel faster-acting insulin aspart (Fiasp) plus pramlintide fully closed-loop system that does not require meal input. Methods: In this open-label, randomised controlled, crossover, non-inferiority trial we compared the Fiasp (Novo Nordisk, Bagsværd, Denmark) plus pramlintide closed-loop system with no meal input (fully artificial pancreas) and the Fiasp-alone closed-loop system with precise carbohydrate counting (hybrid artificial pancreas). Adults (≥18 years) who had a clinical diagnosis of type 1 diabetes for at least 12 months, had glycated haemoglobin 12% or lower, and had been on insulin pump therapy for at least 6 months were enrolled at McGill University Health Centre, Montreal, QC, Canada. The Fiasp plus pramlintide fully closed-loop system delivered pramlintide in a basal-bolus manner with a fixed ratio of 10 μg:U relative to insulin. A research staff member counted the carbohydrate content of meals to input in the hybrid closed-loop system. Participants completed the two full-day crossover interventions in a random order allocated by a computer-generated code implementing a blocked randomisation (block size of four). The primary outcome was the percentage of time spent within the glucose target range (3·9–10·0 mmol/L), with a 6% non-inferiority margin, assessed in all participants who completed both interventions. This trial is registered with ClinicalTrials.gov, NCT03800875. Findings: Between Feb 8, 2019, and Sept 19, 2020, we enrolled 28 adults, of whom 24 completed both interventions and were included in analyses. The percentage of time spent in the target range was 74·3% (IQR 61·5–82·8) with the fully closed-loop system versus 78·1% (66·3–87·5) with the hybrid Fiasp-alone closed-loop system (paired difference 2·6%, 95% CI −2·4 to 12·2; non-inferiority p=0·28). Eight (33%) participants had at least one hypoglycaemia event (
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2589-7500
العلاقة: http://www.sciencedirect.com/science/article/pii/S2589750021001394Test; https://doaj.org/toc/2589-7500Test
DOI: 10.1016/S2589-7500(21)00139-4
الوصول الحر: https://doaj.org/article/15af37e975ca4d9787fbe206eac332ffTest
رقم الانضمام: edsdoj.15af37e975ca4d9787fbe206eac332ff
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:25897500
DOI:10.1016/S2589-7500(21)00139-4