Ellipse method for measuring Liaw’s anteversion of the acetabular component after total hip arthroplasty

التفاصيل البيبلوغرافية
العنوان: Ellipse method for measuring Liaw’s anteversion of the acetabular component after total hip arthroplasty
المؤلفون: Kuei-Lin Yeh, Tai-Yin Wu, Hsuan-Hsiao Ma, Sheng-Mou Hou, Chen-Kun Liaw
المصدر: BMC Musculoskeletal Disorders, Vol 21, Iss 1, Pp 1-6 (2020)
بيانات النشر: BMC, 2020.
سنة النشر: 2020
المجموعة: LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: Anteversion measurement, Ellipse method, Total hip arthroplasty, Liaw’s anteversion, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Background Several cup anteversion measurements for post-operative total hip arthroplasty (THA) surgery have been described. We developed the standardized Liaw’s trigonometric method to eliminate the influence of patient position, which is the most accurate method for cup anteversion measurement. We then developed an ellipse method using the Elliversion software and reported an interobserver error reduction in 2013. In this study, we attempted to apply this ellipse method in the clinic and compared its accuracy with the standard trigonometric version. Methods In the present study, we attempted to incorporate the ellipse method with Liaw’s standardized anteversion in the simulated cup position. We measured standardized Liaw’s anteversion for 434 radiographs in the clinic using the ellipse method. Repeated standard deviation (RSD) was calculated for accuracy evaluation. Furthermore, paired t-test was used for comparison with the interobserver and intraobserver errors. Results We found that the standardized Liaw’s anteversion measured using the ellipse method showed lower RSD than the radiographic version. RSD was 0.795 in the standardized Liaw’s anteversion with ellipse method group. The p-values of the paired t-test were all higher than 0.05 when measuring the interobserver and intraobserver errors. It indicated that the ellipse method was a precise and simple tool for cup anteversion measurement. Conclusion We believe that this ellipse measurement can assist surgeons while placing the acetabulum cup into the precise position and enable early diagnosis of acetabulum loosening.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1471-2474
العلاقة: http://link.springer.com/article/10.1186/s12891-020-03669-5Test; https://doaj.org/toc/1471-2474Test
DOI: 10.1186/s12891-020-03669-5
الوصول الحر: https://doaj.org/article/0b9918384b67472fa00b8708c3b5e69cTest
رقم الانضمام: edsdoj.0b9918384b67472fa00b8708c3b5e69c
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14712474
DOI:10.1186/s12891-020-03669-5