دورية أكاديمية

Development of indirect enzyme-linked immunosorbent assay for detection of porcine epidemic diarrhea virus specific antibodies (IgG) in serum of naturally infected pigs

التفاصيل البيبلوغرافية
العنوان: Development of indirect enzyme-linked immunosorbent assay for detection of porcine epidemic diarrhea virus specific antibodies (IgG) in serum of naturally infected pigs
المؤلفون: Ohnmar Myint, Ayako Yoshida, Satoshi Sekiguchi, Nguyen Van Diep, Naoyuki Fuke, Uda Zahli Izzati, Takuya Hirai, Ryoji Yamaguchi
المصدر: BMC Veterinary Research, Vol 15, Iss 1, Pp 1-8 (2019)
بيانات النشر: BMC, 2019.
سنة النشر: 2019
المجموعة: LCC:Veterinary medicine
مصطلحات موضوعية: Porcine epidemic diarrhea virus, (PEDV), ELISA, Neutralization test, Pre-coated plate, Long-term preservation, Veterinary medicine, SF600-1100
الوصف: Abstract Background Porcine epidemic diarrhea virus (PEDV) infection is a highly contagious infectious disease causing watery diarrhea, vomiting, dehydration and high mortality rate in newborn piglets. PEDV infection can cause high economic losses in pig industry. In Japan, a PEDV outbreak occurred with high mortality from 2013 to 2015. Even though until now, PEDV infection occurs sporadically. For the control and monitoring of PEDV infection, not only symptomatic pigs, but also asymptomatic pigs should be identified. The objective of this study is to develop and optimize novel indirect ELISA as a simple, rapid, sensitive and specific method for the detection of anti-PEDV antibodies and evaluate the efficacy of the assay as a diagnostic method for PED. Results One hundred sixty-two serum samples, consisting of 81 neutralization test (NT) positive and 81 NT negative sera, were applied to the assay. Indirect ELISA test based on whole virus antigen (NK94P6 strain) derived from Vero cell culture was evaluated by receiver operating characteristic (ROC) analysis with neutralization test (NT) as a reference method, and cut-off value was determined as 0.320 with sensitivity and specificity of 92.6 and 90.1%, respectively. The area under curve (AUC) was 0.949, indicating excellent accuracy of indirect ELISA test. There was significant positive correlation between indirect ELISA and neutralization test (R = 0.815, P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1746-6148
العلاقة: http://link.springer.com/article/10.1186/s12917-019-2123-2Test; https://doaj.org/toc/1746-6148Test
DOI: 10.1186/s12917-019-2123-2
الوصول الحر: https://doaj.org/article/038ab80fde7d4a8caa73bedb57cad4feTest
رقم الانضمام: edsdoj.038ab80fde7d4a8caa73bedb57cad4fe
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17466148
DOI:10.1186/s12917-019-2123-2