دورية أكاديمية

Evaluation of Serum Albumin-Coated Bone Allograft for Bone Regeneration: A Seven-Year Follow-Up Study of 26 Cases

التفاصيل البيبلوغرافية
العنوان: Evaluation of Serum Albumin-Coated Bone Allograft for Bone Regeneration: A Seven-Year Follow-Up Study of 26 Cases
المؤلفون: Kata K. Gyulay, Péter Karászi, Mátyás Rédei, Petra Sólymos, Károly Schandl, Zsombor Lacza, Dénes B. Horváthy
المصدر: International Journal of Molecular Sciences, Vol 24, Iss 11, p 9232 (2023)
بيانات النشر: MDPI AG
سنة النشر: 2023
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: serum albumin, bone allograft, bone substitute, BoneAlbumin, bone–tendon–bone autograft, BTB, Biology (General), QH301-705.5, Chemistry, QD1-999
الوصف: We have previously reported that serum albumin-coated bone allograft (BoneAlbumin, BA) is an effective bone substitute. It improves bone regeneration at the patellar and tibial donor sites six months after harvesting bone-patellar tendon-bone (BPTB) autografts for primary anterior cruciate ligament reconstruction (ACLR). In the present study, we examined these donor sites seven years after implantation. The study group (N = 10) received BA-enhanced autologous cancellous bone at the tibial and BA alone at the patellar site. The control group (N = 16) received autologous cancellous bone at the tibial and blood clot at the patellar site. We evaluated subcortical density, cortical thickness, and bone defect volume via CT scans. At the patellar site, subcortical density was significantly higher in the BA group at both time points. There was no significant difference in cortical thickness between the two groups at either donor site. The control group’s bone defect significantly improved and reached the BA group’s values at both sites by year seven. Meanwhile, the bone defects in the BA group did not change significantly and were comparable to the six-month measurements. No complications were observed. There are two limitations in this study: The number of patients recruited is small, and the randomization of the patients could have improved the quality of the study as the control group patients were older compared to the study group patients. Our 7-year results seem to demonstrate that BA is a safe and effective bone substitute that supports faster regeneration of donor sites and results in good-quality bone tissue at the time of ACLR with BPTB autografts. However, studies with a larger number of patients are required to definitively confirm the preliminary results of our study.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 1422-0067
1661-6596
العلاقة: https://www.mdpi.com/1422-0067/24/11/9232Test; https://doaj.org/toc/1661-6596Test; https://doaj.org/toc/1422-0067Test; https://doaj.org/article/b42a424c2bfc4314af29bb6597e71409Test
DOI: 10.3390/ijms24119232
الإتاحة: https://doi.org/10.3390/ijms24119232Test
https://doaj.org/article/b42a424c2bfc4314af29bb6597e71409Test
رقم الانضمام: edsbas.FC938C36
قاعدة البيانات: BASE
الوصف
تدمد:14220067
16616596
DOI:10.3390/ijms24119232