دورية أكاديمية

Evaluating the effect of the number of wire of flow diverter stents on the nonstagnated region formation in an aneurysm sac using lagrangian coherent structure and hyperbolic time analysis

التفاصيل البيبلوغرافية
العنوان: Evaluating the effect of the number of wire of flow diverter stents on the nonstagnated region formation in an aneurysm sac using lagrangian coherent structure and hyperbolic time analysis
المؤلفون: Mutlu, Onur, Olcay, Ali Bahadır
المساهمون: Bursa Uludağ Üniversitesi/Tıp Fakültesi/Radyoloji Anabilim Dalı., orcid:0000-0002-3425-0740, Bilgin, Cem, Hakyemez, Bahattin, HHS-7433-2022, AAI-2318-2021, 57200617643, 6602527239
بيانات النشر: Elsevier Science
سنة النشر: 2020
المجموعة: Açık Erişim@BUU (Bursa Uludağ Üniversitesi)
مصطلحات موضوعية: Neurosciences & neurology, Surgery, Computational fluid dynamics, Lagrangian coherent structure, Stagnated and nonstagnated fluid flow zones, Wire number of a flow diverter stent, Blood-flow, Intracranial aneurysms, Embolization device, Left-ventricle, Stagnation, Diversion, Transport, Velocity, Arteries, Volume, Angiography, digital subtraction, Computer simulation, Endovascular procedures, Female, Hemodynamics, Humans, Hydrodynamics, Intracranial aneurysm, Middle aged, Models, biological, Stents, Clinical neurology
الوصف: Background: Giant aneurysms at carotid arteries are typically treated with flow diverter (FD) stents in the clinic. Although the goal of an FD stent is to direct most of the blood flow into the main artery, not much is known regarding the effects of wire number an FD possesses on the hemodynamics inside the aneurysm. Methods: In this study, 48-, 72-, and 96-wire FD stents were separately implanted into the site of aneurysm of a 45-year-old woman to evaluate the effects of the FD's number of wires on fluid flow behavior in the aneurysm sac. Time evolution of both finite-time Lyapunov exponent (FTLE) and hyperbolic time fields in the aneurysm sac were calculated by using computational fluid dynamics along with Lagrangian coherent structure (LCS) methods. Results: The computations reveal that a 48-wire FD stent allows a large amount of blood to enter inside the aneurysm sac revealing scattered nonstagnant flow zones formation. Besides, time-dependent results of LCS analysis show that most of the blood flow is diverted into the main artery when 72- and 96-wire number Surpass brand FD stents are separately implanted into the site of the aneurysm, yielding a small amount of blood flow to penetrate into the aneurysm sac. Conclusions: Furthermore, FTLE and hyperbolic time field plots are in good agreement with the patient's digital subtraction angiography image captured 3.5 minutes after 72-wire Surpass brand FD stent implantation.
نوع الوثيقة: article in journal/newspaper
اللغة: English
ردمك: 978-1-878875-01-3
1-878875-01-9
تدمد: 1878-8750
1878-8769
العلاقة: 117M491; Makale - Uluslararası Hakemli Dergi; World Neurosurgery; Yurt içi; Mutlu, O. vd. (2020) ."Evaluating the effect of the number of wire of flow diverter stents on the nonstagnated region formation in an aneurysm sac using lagrangian coherent structure and hyperbolic time analysis". World Neurosurgery, 133, e666-e682.; https://www.sciencedirect.com/science/article/pii/S1878875019325574Test; https://hdl.handle.net/11452/39609Test; 000503993700131; 2-s2.0-85074725931; E666; E682; 133; https://doi.org/10.1016/j.wneu.2019.09.116Test
DOI: 10.1016/j.wneu.2019.09.116
الإتاحة: https://doi.org/10.1016/j.wneu.2019.09.116Test
https://hdl.handle.net/11452/39609Test
https://www.sciencedirect.com/science/article/pii/S1878875019325574Test
حقوق: info:eu-repo/semantics/closedAccess
رقم الانضمام: edsbas.FBCE2038
قاعدة البيانات: BASE
الوصف
ردمك:9781878875013
1878875019
تدمد:18788750
18788769
DOI:10.1016/j.wneu.2019.09.116