دورية أكاديمية

Validation of plasma amino acid profile using UHPLC-mass spectrometer (QDa) as a screening method in a metabolic disorders reference centre: Performance and accreditation concerns

التفاصيل البيبلوغرافية
العنوان: Validation of plasma amino acid profile using UHPLC-mass spectrometer (QDa) as a screening method in a metabolic disorders reference centre: Performance and accreditation concerns
المؤلفون: Bruno, C, Veyrat-Durebex, C, Lumbu Lukuntonda, C H, Andres, C R, Moreau, Nicolas, Bendavid, C, Homedan, C, Labarthe, F, Tardieu, M, Bigot, A, Maillot, F, Benz-de Bretagne, I, Blasco, H
المساهمون: Imaging, Brain & Neuropsychiatry (iBraiN), Université de Tours (UT)-Institut National de la Santé et de la Recherche Médicale (INSERM), Centre Hospitalier Régional Universitaire de Tours (CHRU Tours), Nutrition, Métabolismes et Cancer (NuMeCan), Université de Rennes (UR)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Institut National de Recherche pour l’Agriculture, l’Alimentation et l’Environnement (INRAE), Centre Hospitalier Universitaire de Rennes CHU Rennes = Rennes University Hospital Ponchaillou, Centre Hospitalier Universitaire d'Angers (CHU Angers), PRES Université Nantes Angers Le Mans (UNAM), Niche, Nutrition, Cancer et métabolisme oxydatif (N2Cox), No funding
المصدر: ISSN: 0009-9120.
بيانات النشر: HAL CCSD
Elsevier
سنة النشر: 2021
المجموعة: Université François-Rabelais de Tours: HAL
مصطلحات موضوعية: Aminoacids, Derivatization, Liquid chromatography, Mass spectrometry, [SDV]Life Sciences [q-bio], [SDV.BBM]Life Sciences [q-bio]/Biochemistry, Molecular Biology
الوصف: International audience ; INTRODUCTION: Amino acid (AA) analysis in plasma is essential for diagnosis and monitoring of inborn errors of metabolism (IEM). The efficacy of patient management is governed by the rapidity of AA profile availability, along with the robustness of the method. French quality guidelines and progress made in analytical techniques have led biologists to develop AA profile exploration via mass spectrometry (MS). OBJECTIVES: The aim of this study was to validate an analytical method with a single quadrupole mass spectrometer (MS) and to suggest reference values in regard to French quality and IEM society recommendations. DESIGN AND METHODS: Plasma samples from patients were deproteinised and derivatised with AccqTag™ reagent. Analysis was performed by reverse-phase chromatography coupled to QDA detector. We evaluated accuracy, intra-days and inter-days precision and limit of quantification by the β-expectation tolerance interval method for 27 AA. Method comparison was performed with the standard method (ion exchange chromatography, IEC) on Jeol Aminotac® and to tandem MS. Reference values were established on AA concentrations of the cohort of patients who had no IEM. RESULTS: Our method allowed the separations of almost all amino acids with a total run time of 12 min. Separation of isoleucine and alloisoleucine was incomplete (R = 0.55) but without impact on biological interpretation. Precision, accuracy and quantification were satisfactory (intra-days coefficient of variation (CV) was <5%, inter-days precision CV <10% and accuracy <15%). The limits of quantification were validated between 1 and 900 µmol/L. Results were comparable between the new method and IEC. CONCLUSION: Ultimately, we validated a rapid method on plasma for quantifying 27 amino acids that can be used in routine practice, according to French quality laboratories and SFEIM (French Society of Inborn Error of Metabolism) recommendations. Furthermore, estimated reference values were similar to those found in published ...
نوع الوثيقة: article in journal/newspaper
اللغة: English
العلاقة: info:eu-repo/semantics/altIdentifier/pmid/33736999; hal-03194389; https://hal.science/hal-03194389Test; https://hal.science/hal-03194389/documentTest; https://hal.science/hal-03194389/file/Bruno%20et%20al.%20-%202021%20-%20Validation%20of%20plasma%20amino%20acid%20profile%20using%20UHPL.pdfTest; PUBMED: 33736999; WOS: 000653089100005
DOI: 10.1016/j.clinbiochem.2021.03.004
الإتاحة: https://doi.org/10.1016/j.clinbiochem.2021.03.004Test
https://hal.science/hal-03194389Test
https://hal.science/hal-03194389/documentTest
https://hal.science/hal-03194389/file/Bruno%20et%20al.%20-%202021%20-%20Validation%20of%20plasma%20amino%20acid%20profile%20using%20UHPL.pdfTest
حقوق: info:eu-repo/semantics/OpenAccess
رقم الانضمام: edsbas.F6F228C6
قاعدة البيانات: BASE