LUX trigger efficiency

التفاصيل البيبلوغرافية
العنوان: LUX trigger efficiency
المؤلفون: Akerib, D. S., Alsum, S., Araújo, H. M., Bai, X., Balajthy, J., Beltrame, P., Bernard, E. P., Bernstein, A., Biesiadzinski, T. P., Boulton, E. M., B. Boxer, Brás, P., S. Burdin, Byram, D., Carmona-Benitez, M. C., Chan, C., Cutter, J. E., Davison, T. J.R., Druszkiewicz, E., Fallon, S. R., Fan, A., Fiorucci, S., Gaitskell, R. J., Genovesi, J., Ghag, C., Gilchriese, M. G.D., E. Grace, C. Gwilliam, Hall, C. R., Haselschwardt, S. J., Hertel, S. A., Hogan, D. P., Horn, M., Huang, D. Q., Ignarra, C. M., Jacobsen, R. G., Ji, W., Kamdin, K., Kazkaz, K., Khaitan, D., Knoche, R., E.V. Korolkova, S. Kravitz, V.A. Kudryavtsev, Lenardo, B. G., Lesko, K. T., Liao, J., J. Lin, Lindote, A., Lopes, M. I., Manalaysay, A., Mannino, R. L., Marangou, N., Marzioni, M. F., McKinsey, D. N., Mei, D. -M., Moongweluwan, M., Morad, J. A., Murphy, A. St.J., Nehrkorn, C., Nelson, H. N., Neves, F., Oliver-Mallory, K. C., Palladino, K. J., Pease, E. K., G. Rischbieter, Rhyne, C., P. Rossiter, Shaw, S., Shutt, T. A., Silva, C., Solmaz, M., Solovov, V. N., Sorensen, P., Sumner, T. J., Szydagis, M., Taylor, D. J., Taylor, W. C., Tennyson, B. P., Terman, P. A., Tiedt, D. R., To, W. H., Tripathi, M., Tvrznikova, L., Utku, U., Uvarov, S., Velan, V., Verbus, J. R., Webb, R. C., White, J. T., Whitis, T. J., Witherell, M. S., Wolfs, F. L.H., D. Woodward, Xu, J., Yazdani, K., Zhang, C.
سنة النشر: 2023
المجموعة: SciTec Connect (Office of Scientific and Technical Information - OSTI, U.S. Department of Energy)
مصطلحات موضوعية: 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY, 79 ASTRONOMY AND ASTROPHYSICS
الوصف: The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. Here, the trigger efficiency, which is defined as the probability that an event of interest is selected for offline analysis, is studied using raw data obtained from both electron recoil (ER) and nuclear recoil (NR) calibrations. The measured efficiency exceeds 98% at a pulse area of 90 detected photons, which is well below the WIMP analysis threshold on the S2 pulse area. The efficiency also exceeds 98% at recoil energies of 1.3 keV and above, for both ER and NR. In conclusion, the measured trigger efficiency varies between 99% and 100% over the fiducial volume of the detector.
نوع الوثيقة: other/unknown material
وصف الملف: application/pdf
اللغة: unknown
العلاقة: http://www.osti.gov/servlets/purl/1866185Test; https://www.osti.gov/biblio/1866185Test; https://doi.org/10.1016/j.nima.2018.07.094Test
DOI: 10.1016/j.nima.2018.07.094
الإتاحة: https://doi.org/10.1016/j.nima.2018.07.094Test
http://www.osti.gov/servlets/purl/1866185Test
https://www.osti.gov/biblio/1866185Test
رقم الانضمام: edsbas.F5C4E160
قاعدة البيانات: BASE