دورية أكاديمية

A new sports garment with elastomeric technology optimizes physiological, mechanical, and psychological acute responses to pushing upper-limb resistance exercises

التفاصيل البيبلوغرافية
العنوان: A new sports garment with elastomeric technology optimizes physiological, mechanical, and psychological acute responses to pushing upper-limb resistance exercises
المؤلفون: Saez-Berlanga, Angel, Babiloni-Lopez, Carlos, Ferri-Caruana, Ana, Jiménez-Martínez, Pablo, García-Ramos, Amador, Flandez, Jorge, Gene-Morales, Javier, Colado, Juan C.
المصدر: PeerJ ; volume 12, page e17008 ; ISSN 2167-8359
بيانات النشر: PeerJ
سنة النشر: 2024
المجموعة: PeerJ (E-Journal - via CrossRef)
الوصف: This study aimed to compare the mechanical (lifting velocity and maximum number of repetitions), physiological (muscular activation, lactate, heart rate, and blood pressure), and psychological (rating of perceived exertion) responses to upper-body pushing exercises performed wearing a sports elastomeric garment or a placebo garment. Nineteen physically active young adults randomly completed two training sessions that differed only in the sports garment used (elastomeric technology or placebo). In each session, subjects performed one set of seated shoulder presses and another set of push-ups until muscular failure. The dependent variables were measured immediately after finishing the set of each exercise. Compared to the placebo garment, the elastomeric garment allowed participants to obtain greater muscular activation in the pectoralis major (push-ups: p = 0.04, d = 0.49; seated shoulder press: p < 0.01, d = 0.64), triceps brachialis (push-ups, p < 0.01, d = 0.77; seated shoulder press: p < 0.01, d = 0.65), and anterior deltoid (push-ups: p < 0.01, d = 0.72; seated shoulder press: p < 0.01, d = 0.83) muscles. Similarly, participants performed more repetitions (push-ups: p < 0.01; d = 0.94; seated shoulder press: p = 0.03, d = 0.23), with higher movement velocity (all p ≤ 0.04, all d ≥ 0.47), and lower perceived exertion in the first repetition (push-ups: p < 0.01, d = 0.61; seated shoulder press: p = 0.05; d = 0.76) wearing the elastomeric garment compared to placebo. There were no between-garment differences in most cardiovascular variables (all p ≥ 0.10). Higher diastolic blood pressure was only found after the seated shoulder press wearing the elastomeric garment compared to the placebo ( p = 0.04; d = 0.49). Finally, significantly lower blood lactate levels were achieved in the push-ups performed wearing the elastomeric garment ( p < 0.01; d = 0.91), but no significant differences were observed in the seated shoulder press ( p = 0.08). Overall, the findings of this study suggest that ...
نوع الوثيقة: article in journal/newspaper
اللغة: English
DOI: 10.7717/peerj.17008
الإتاحة: https://doi.org/10.7717/peerj.17008Test
https://peerj.com/articles/17008.pdfTest
https://peerj.com/articles/17008.xmlTest
https://peerj.com/articles/17008.htmlTest
حقوق: https://creativecommons.org/licenses/by/4.0Test/
رقم الانضمام: edsbas.F4206732
قاعدة البيانات: BASE