دورية أكاديمية

Patient-specific neurosurgical phantom: assessment of visual quality, accuracy, and scaling effects

التفاصيل البيبلوغرافية
العنوان: Patient-specific neurosurgical phantom: assessment of visual quality, accuracy, and scaling effects
المؤلفون: Felipe Wilker Grillo, Victor Hugo Souza, Renan Hiroshi Matsuda, Carlo Rondinoni, Theo Zeferino Pavan, Oswaldo Baffa, Helio Rubens Machado, Antonio Adilton Oliveira Carneiro
المصدر: 3D Printing in Medicine, Vol 4, Iss 1, Pp 1-9 (2018)
بيانات النشر: BMC
سنة النشر: 2018
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: Neurosurgery, Education, Medical training, Patient-specific, Neuronavigation, Phantom, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Background Training in medical education depends on the availability of standardized materials that can reliably mimic the human anatomy and physiology. One alternative to using cadavers or animal bodies is to employ phantoms or mimicking devices. Styrene-ethylene/butylene-styrene (SEBS) gels are biologically inert and present tunable properties, including mechanical properties that resemble the soft tissue. Therefore, SEBS is an alternative to develop a patient-specific phantom, that provides real visual and morphological experience during simulation-based neurosurgical training. Results A 3D model was reconstructed and printed based on patient-specific magnetic resonance images. The fused deposition of polyactic acid (PLA) filament and selective laser sintering of polyamid were used for 3D printing. Silicone and SEBS materials were employed to mimic soft tissues. A neuronavigation protocol was performed on the 3D-printed models scaled to three different sizes, 100%, 50%, and 25% of the original dimensions. A neurosurgery team (17 individuals) evaluated the phantom realism as “very good” and “perfect” in 49% and 31% of the cases, respectively, and rated phantom utility as “very good” and “perfect” in 61% and 32% of the cases, respectively. Models in original size (100%) and scaled to 50% provided a quantitative and realistic visual analysis of the patient’s cortical anatomy without distortion. However, reduction to one quarter of the original size (25%) hindered visualization of surface details and identification of anatomical landmarks. Conclusions A patient-specific phantom was developed with anatomically and spatially accurate shapes, that can be used as an alternative for surgical planning. Printed models scaled to sizes that avoided quality loss might save time and reduce medical training costs.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 2365-6271
العلاقة: http://link.springer.com/article/10.1186/s41205-018-0025-8Test; https://doaj.org/toc/2365-6271Test; https://doaj.org/article/378068dd2ab14eebbd1b34a61f8d1b10Test
DOI: 10.1186/s41205-018-0025-8
الإتاحة: https://doi.org/10.1186/s41205-018-0025-8Test
https://doaj.org/article/378068dd2ab14eebbd1b34a61f8d1b10Test
رقم الانضمام: edsbas.EE511EE
قاعدة البيانات: BASE
الوصف
تدمد:23656271
DOI:10.1186/s41205-018-0025-8