دورية أكاديمية

Impedance cardiography applied to maximal arm cranking exercise: a matter of sampling and processing strategy

التفاصيل البيبلوغرافية
العنوان: Impedance cardiography applied to maximal arm cranking exercise: a matter of sampling and processing strategy
المؤلفون: Theisen, Daniel, Francaux, Marc, Michotte de Welle, Jacques, Sturbois, Xavier
المساهمون: UCL - MD/IEPR - Institut d'éducation physique et de réadaptation
المصدر: Medicine and Science in Sports and Exercise, Vol. 30, no. 8, p. 1321-1327 (1998)
بيانات النشر: Lippincott Williams & Wilkins
سنة النشر: 1998
المجموعة: DIAL@USL-B (Université Saint-Louis, Bruxelles)
مصطلحات موضوعية: Adult, Cardiac Output, Cardiography, Impedance, Exercise, Hemodynamics, Humans, Male, Stroke Volume, Central hemodynamics, Ensemble-averaging, Signal conditioning, Artifacts
الوصف: PURPOSE: A new ensemble-averaging (EA) approach was developed with the goal of investigating central hemodynamics by transthoracic impedance cardiography during maximal arm cranking. This EA procedure of the first time derivative of impedance changes (dZ/dt) over several cardiac cycles differs from previously reported techniques with respect to cycle selection strategy, according to fixed criteria, and processing methods. METHODS: First, the primary elements of the Kubicek stroke volume (SV) formula, as determined by EA, were compared with the values determined by the standard hand-processing (HP) method over a large range of cardiac outputs. RESULTS: Results showed a very high reliability for ventricular ejection time (r = 0.996), (dZ/dt)min (r = 0.995), SV (r = 0.977), and heart rate (r = 0.999). Second, the EA procedure was applied to six subjects performing a continuous, multistage arm cranking test to volitional fatigue. The present technique allowed for an effective filtering of movement and breathing artifacts of the original signal. Thus, interpretation of the dZ/dt wave form was convenient, even at maximal arm cranking power outputs up to 120 W. Stroke volume ranged from 63.83 to 127.18 mL.beat-1, showing no significant variations with oxygen consumption. Cardiac output increased linearly with oxygen uptake, reaching a mean maximal value of 16 L.min-1. CONCLUSION: The present procedure opens a new field of application to impedance cardiography, permitting to measure cardiac output during maximal arm cranking exercise.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 0195-9131
1530-0315
العلاقة: boreal:12457; http://hdl.handle.net/2078.1/12457Test; info:pmid/9710876; urn:ISSN:0195-9131; urn:EISSN:1530-0315
DOI: 10.1097/00005768-199808000-00022
الإتاحة: https://doi.org/10.1097/00005768-199808000-00022Test
http://hdl.handle.net/2078.1/12457Test
حقوق: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.E54147D4
قاعدة البيانات: BASE
الوصف
تدمد:01959131
15300315
DOI:10.1097/00005768-199808000-00022