Measurement of the eta mass at KLOE

التفاصيل البيبلوغرافية
العنوان: Measurement of the eta mass at KLOE
المؤلفون: AMBROSINO, FABIO, A. Antonelli, M. Antonelli, F. Archilli, C. Bacci, P. Beltrame, G. Bencivenni, S. Bertolucci, C. Bini, C. Bloise, S. Bocchetta, V. Bocci, F. Bossi, P. Branchini, R. Caloi, P. Campana, G. Capon, CAPUSSELA, TIZIANA, F. Ceradini, S. Chi, G. Chiefari, P. Ciambrone, E. D. Lucia, A. D. Santis, P. D. Simone, G. D. Zorzi, A. Denig, A. D. Domenico, C. D. Donato, S. D. Falco, B. D. Micco, A. Doria, M. Dreucci, G. Felici, A. Ferrari, M. L. Ferrer, G. Finocchiaro, S. Fiore, C. Forti, P. Franzini, C. Gatti, P. Gauzzi, S. Giovannella, E. Gorini, E. Graziani, M. Incagli, W. Kluge, V. Kulikov, F. Lacava, G. Lanfranchi, J. Lee Franzini, D. Leone, M. Martini, MASSAROTTI, PAOLO, W. Mei, S. Meola, S. Miscetti, M. Moulson, S. M��ller, F. Murtas, M. Napolitano, F. Nguyen, M. Palutan, E. Pasqualucci, A. Passeri, V. Patera, PERFETTO, FRANCESCO, M. Primavera, P. Santangelo, G. Saracino, B. Sciascia, A. Sciubba, F. Scuri, I. Sfiligoi, T. Spadaro, M. Testa, L. Tortora, P. Valente, B. Valeriani, G. Venanzoni, R. Versaci, G. Xu
المساهمون: Ambrosino, Fabio, A., Antonelli, M., Antonelli, F., Archilli, C., Bacci, P., Beltrame, G., Bencivenni, S., Bertolucci, C., Bini, C., Bloise, S., Bocchetta, V., Bocci, F., Bossi, P., Branchini, R., Caloi, P., Campana, G., Capon, Capussela, Tiziana, F., Ceradini, S., Chi, G., Chiefari, P., Ciambrone, E. D., Lucia, A. D., Santi, P. D., Simone, G. D., Zorzi, A., Denig, A. D., Domenico, C. D., Donato, S. D., Falco, B. D., Micco, A., Doria, M., Dreucci, G., Felici, A., Ferrari, M. L., Ferrer, G., Finocchiaro, S., Fiore, C., Forti, P., Franzini, C., Gatti, P., Gauzzi, S., Giovannella, E., Gorini, E., Graziani, M., Incagli, W., Kluge, V., Kulikov, F., Lacava, G., Lanfranchi, J., Lee Franzini, D., Leone, M., Martini, Massarotti, Paolo, W., Mei, S., Meola, S., Miscetti, M., Moulson, S., M��ller, F., Murta, M., Napolitano, F., Nguyen, M., Palutan, E., Pasqualucci, A., Passeri, V., Patera, Perfetto, Francesco, M., Primavera, P., Santangelo, G., Saracino, B., Sciascia, A., Sciubba, F., Scuri, I., Sfiligoi, T., Spadaro, M., Testa, L., Tortora, P., Valente, B., Valeriani, G., Venanzoni, R., Versaci, G., Xu
بيانات النشر: D. Son, S.K. Oh. Daegu, Kyungpook Nat. Univ. Pr
Daegu
سنة النشر: 2007
المجموعة: IRIS Università degli Studi di Napoli Federico II
مصطلحات موضوعية: Cross check, Detector response, Energy calibration, Integrated luminosity, Energy management, Energy resources, Human computer interaction, Photons
الوصف: An integrated luminosity of 410 pb-1, corresponding to ��� 17 million of �� events, has been analyzed to measure the �� mass using the decay �� ��� ����. The measurement is insensitive to the calorimeter energy calibration and the systematic error on the measurement is dominated by the uniformity of the detector response. As a cross check of the method the ��0 mass from the decay �� ��� ��0, ��0 ��� has been measured and it is in agreement with the most accurate previous determinations. The result obtained is m �� = 547.873��0.007stat. ��0.031syst. MeV, that is today best measurement of the �� mass.
نوع الوثيقة: conference object
اللغة: unknown
العلاقة: ispartofbook:23rd International Symposium on Lepton-Photon Interactions at High Energy, LP 2007; 23rd International Symposium on Lepton-Photon Interactions at High Energy, LP 2007; http://hdl.handle.net/11588/597910Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84884849634; http://www.scopus.com/inward/record.url?eid=2-s2.0-84884849634&partnerID=40&md5=228a38ab88854d62c73e9cb2d1ac242eTest
الإتاحة: http://hdl.handle.net/11588/597910Test
http://www.scopus.com/inward/record.url?eid=2-s2.0-84884849634&partnerID=40&md5=228a38ab88854d62c73e9cb2d1ac242eTest
رقم الانضمام: edsbas.DE48AF25
قاعدة البيانات: BASE