دورية أكاديمية

Towards optimizing single pulse electrical stimulation: High current intensity, short pulse width stimulation most effectively elicits evoked potentials

التفاصيل البيبلوغرافية
العنوان: Towards optimizing single pulse electrical stimulation: High current intensity, short pulse width stimulation most effectively elicits evoked potentials
المؤلفون: Hays, Mark A, Kamali, Golnoosh, Koubeissi, Mohamad Z, Sarma, Sridevi V, Crone, Nathan E, Smith, Rachel J, Kang, Joon Y
المصدر: GW Authored Works
بيانات النشر: Health Sciences Research Commons
سنة النشر: 2023
المجموعة: George Washington University: Health Sciences Research Commons (HSRC)
مصطلحات موضوعية: Cortico-cortical evoked potential, Effective connectivity, Intracranial EEG, Single pulse electrical stimulation
الوصف: BACKGROUND: While single pulse electrical stimulation (SPES) is increasingly used to study effective connectivity, the effects of varying stimulation parameters on the resulting cortico-cortical evoked potentials (CCEPs) have not been systematically explored. OBJECTIVE: We sought to understand the interacting effects of stimulation pulse width, current intensity, and charge on CCEPs through an extensive testing of this parameter space and analysis of several response metrics. METHODS: We conducted SPES in 11 patients undergoing intracranial EEG monitoring using five combinations of current intensity (1.5, 2.0, 3.0, 5.0, and 7.5 mA) and pulse width at each of three charges (0.750, 1.125, and 1.500 μC/phase) to study how CCEP amplitude, distribution, latency, morphology, and stimulus artifact amplitude vary with each parameter. RESULTS: Stimulations with a greater charge or a greater current intensity and shorter pulse width at a given charge generally resulted in greater CCEP amplitudes and spatial distributions, shorter latencies, and increased waveform correlation. These effects interacted such that stimulations with the lowest charge and highest current intensities resulted in greater response amplitudes and spatial distributions than stimulations with the highest charge and lowest current intensities. Stimulus artifact amplitude increased with charge, but this could be mitigated by using shorter pulse widths. CONCLUSIONS: Our results indicate that individual combinations of current intensity and pulse width, in addition to charge, are important determinants of CCEP magnitude, morphology, and spatial extent. Together, these findings suggest that high current intensity, short pulse width stimulations are optimal SPES settings for eliciting strong and consistent responses while minimizing charge.
نوع الوثيقة: text
اللغة: unknown
العلاقة: https://hsrc.himmelfarb.gwu.edu/gwhpubs/2958Test; https://doi.org/10.1016/j.brs.2023.04.023Test
DOI: 10.1016/j.brs.2023.04.023
الإتاحة: https://doi.org/10.1016/j.brs.2023.04.023Test
https://hsrc.himmelfarb.gwu.edu/gwhpubs/2958Test
رقم الانضمام: edsbas.CA460410
قاعدة البيانات: BASE