التفاصيل البيبلوغرافية
العنوان: |
Assessment of coronary spasms with transluminal attenuation gradient in coronary computed tomography angiography |
المؤلفون: |
Park, Jae Yang, Kang, Eun-Ju, Kim, Moo Hyun, Yong, Hwan Seok, Rha, Seung-Woon |
المساهمون: |
Tebaldi, Matteo, Dong-A University |
المصدر: |
PLOS ONE ; volume 17, issue 7, page e0271189 ; ISSN 1932-6203 |
بيانات النشر: |
Public Library of Science (PLoS) |
سنة النشر: |
2022 |
المجموعة: |
PLOS Publications (via CrossRef) |
الوصف: |
Purpose To evaluate the imaging features of coronary spasm, including transluminal attenuation gradient (TAG) on coronary computed tomography angiography (CCTA), in patients with vasospastic angina (VA). Methods A total of 43 patients with a high clinical likelihood of VA were included in the study. All the subjects underwent double CCTA acquisition: CCTA without a vasodilator (‘baseline CT’) and CCTA during continuous intravenous nitrate infusion (‘IV nitrate CT’). A catheterized ergonovine provocation test was used to determine true VA patients. Coronary spasm is classified into focal- and diffuse-types according to morphological differences. We measured TAG and contrast enhancement of the proximal ostium (ProxHU) of each coronary artery for both the baseline and IV nitrate CT. Results Twenty-four patients (55.8%) showed positive results of coronary vasospasm on the provocation test. Thirty-eight vessels showed coronary spasms (29.5%): Focal-type in nine vessels (24%), and diffuse-type in 29 (76%). In the baseline CT, LCX showed significantly lower (steeper) TAG in spasm(+) vessels than in spasm(-) vessels, while LAD and RCA showed no significant differences in TAG. The ProxHU of LAD showed significantly lower values in spasm(+) vessels than in spasm(-) vessels, while the other vessels did not show significant differences in ProxHU. For IV nitrate CT, there were no significant differences in either the TAG and ProxHU between spasm(+) and (-) vessels for all the three vessel types. In subgroup analysis for spasm(+) vessels, diffuse spasms showed significantly lower TAG than focal spasms, while the ProxHU did not differ between the two types of spasm. Conclusions A relatively large percentage of coronary spasms present as diffuse type, and the TAG values significantly differed according to the morphological type of the coronary spasm. |
نوع الوثيقة: |
article in journal/newspaper |
اللغة: |
English |
DOI: |
10.1371/journal.pone.0271189 |
الإتاحة: |
https://doi.org/10.1371/journal.pone.0271189Test |
حقوق: |
http://creativecommons.org/licenses/by/4.0Test/ |
رقم الانضمام: |
edsbas.B58B55C1 |
قاعدة البيانات: |
BASE |