دورية أكاديمية
Influences of topical cyclopentolate on anterior chamber parameters with a dual-scheimpflug analyzer in healthy children
العنوان: | Influences of topical cyclopentolate on anterior chamber parameters with a dual-scheimpflug analyzer in healthy children |
---|---|
المؤلفون: | Güler, E., Güragaç, F.B., Tenlik, A., Yagci, R., Arslanyilmaz, Z., Balci, M. |
بيانات النشر: | Slack Incorporated |
سنة النشر: | 2015 |
المجموعة: | Pamukkale University Repository / Pamukkale Üniversitesi Açık Erişim Arşivi |
مصطلحات موضوعية: | eye drops, cyclopentolate, mydriatic agent, adolescent, anterior chamber volume, anterior eye chamber, anterior eye chamber angle, anterior eye chamber depth, anterior segment parameter, Article, central corneal thickness, child, clinical article, cornea topographer, drug effect, female, human, male, pupil, Student t test, visual system parameters, anatomy and histology, cornea, devices, normal human, physiology, preschool child, prospective study, topical drug administration, visual system examination |
الوصف: | Purpose: To evaluate the changes of anterior segment parameters following the topical instillation of cyclopentolate hydrochloride 1% with the Galilei dual-Scheimpflug analyzer (GSA) (Ziemer Ophthalmology Co., Port, Switzerland) in healthy children. Methods: Fifty children (29 boys, 21 girls) were evaluated before and 60 minutes after instillation of three drops of 1% cyclopentolate hydrochloride using the GSA. The measurements before and after cycloplegia, including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and pupil size, were evaluated using the paired t test. Results: The mean age of the patients was 10.27 ± 3.32 years (range: 5 to 15 years). Measurements between the two sessions were significantly different for all parameters (P .05), except for CCT (P > .05). Conclusions: The GSA demonstrated a statistically significant increase in ACD, ACV, ACA, and pupil size following the topical application of cyclopentolate hydrochloride 1%. These results should be considered during biometric measurement and refractive surgery planning. © SLACK Incorporated. |
نوع الوثيقة: | article in journal/newspaper |
اللغة: | English |
تدمد: | 0191-3913 |
العلاقة: | Journal of Pediatric Ophthalmology and Strabismus; Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı; https://doi.org/10.3928/01913913-20141111-02Test; https://hdl.handle.net/11499/10497Test; 52; 26; 30; 2-s2.0-84928190734; WOS:000351639500008 |
DOI: | 10.3928/01913913-20141111-02 |
الإتاحة: | https://doi.org/10.3928/01913913-20141111-02Test https://hdl.handle.net/11499/10497Test |
حقوق: | none |
رقم الانضمام: | edsbas.A3C5EFA6 |
قاعدة البيانات: | BASE |
تدمد: | 01913913 |
---|---|
DOI: | 10.3928/01913913-20141111-02 |