دورية أكاديمية

Towards a repository of synthetic electrograms for atrial activation detection in atrial fibrillation

التفاصيل البيبلوغرافية
العنوان: Towards a repository of synthetic electrograms for atrial activation detection in atrial fibrillation
المؤلفون: Valinoti, Maddalena, Masci, Alessandro, Berto, Francesca, Severi, Stefano, Corsi, Cristiana
المساهمون: Valinoti, Maddalena, Masci, Alessandro, Berto, Francesca, Severi, Stefano, Corsi, Cristiana*
سنة النشر: 2018
المجموعة: IRIS Università degli Studi di Bologna (CRIS - Current Research Information System)
مصطلحات موضوعية: Atrial fibrillation, Biomedical signal processing, Synthetic atrial electrogram, Computer Science Applications1707 Computer Vision and Pattern Recognition, Health Informatics
الوصف: Background: Recently, the analysis of the spatio-temporal behavior of atrial fibrillation activation patterns has been widely investigated with the aim to better understand the arrhythmia implications on the heart electrical activity. Most of the proposed techniques are based on atrial activation timing detections. Unfortunately atrial activation timings are not easily recognizable on the electrograms (EGMs) and an approach to support the validation of such techniques is highly desirable. The aim of this study is to provide an effective workflow for the generation of synthetic unipolar atrial electrograms (SEGMs) in atrial fibrillation (AF) condition and with different levels of noise. Method: Real EGMs signals were obtained from a dataset of 6 subjects that underwent ablation. Each SEGM was obtained by modeling the three principal components of an EGM starting from real signals: atrial far-field (Afar), atrial near-field (Anear) and the ventricular far-field (Vfar). Afar was generated using an autoregressive model applied on segments from real EGMs not characterized by ventricular or atrial activations; Anear and Vfar were extracted directly from the real signals. A Gamma distribution and an atrio-ventricular node model were used to locate both Anear and Vfar on Afar, respectively. Three electrophysiologists with different levels of expertise evaluated the realism of the SEGMs on a set of 100 randomly selected signals including 50 EGMs and 50 SEGMs. Analysis was repeated by the three experts on a subset of 21 signals. Results: The time required to generate the synthetic EGMs was less than 1 min once annotated EGMs are available. The cardiologists succeeded in distinguishing real from synthetic EGMs in 45%, 43% and 35% of the signals, respectively. By repeating the evaluation, 28%, 0% and 48% of signals were classified differently, including 67%, 52% and 36% of correct classifications. Conclusion: The proposed approach proved to be effective in producing SEGMs which are difficult to distinguish from real EGMs. ...
نوع الوثيقة: article in journal/newspaper
وصف الملف: ELETTRONICO
اللغة: English
العلاقة: info:eu-repo/semantics/altIdentifier/pmid/30212744; info:eu-repo/semantics/altIdentifier/wos/WOS:000446282300024; volume:101; firstpage:229; lastpage:235; numberofpages:7; journal:COMPUTERS IN BIOLOGY AND MEDICINE; http://hdl.handle.net/11585/661898Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85053033032; www.elsevier.com/locate/compbiomed
DOI: 10.1016/j.compbiomed.2018.09.001
الإتاحة: https://doi.org/10.1016/j.compbiomed.2018.09.001Test
http://hdl.handle.net/11585/661898Test
رقم الانضمام: edsbas.8DA8BFB7
قاعدة البيانات: BASE