دورية أكاديمية

Development of a Deep Learning–Based System for Optic Nerve Characterization in Transorbital Ultrasound Images on a Multicenter Data Set

التفاصيل البيبلوغرافية
العنوان: Development of a Deep Learning–Based System for Optic Nerve Characterization in Transorbital Ultrasound Images on a Multicenter Data Set
المؤلفون: Francesco Marzola, Piergiorgio Lochner, Andrea Naldi, Robert Lemor, Jakob Stögbauer, Kristen M. Meiburger
المساهمون: Marzola, Francesco, Lochner, Piergiorgio, Naldi, Andrea, Lemor, Robert, Stögbauer, Jakob, Meiburger, Kristen M.
بيانات النشر: Elsevier
سنة النشر: 2023
المجموعة: PORTO@iris (Publications Open Repository TOrino - Politecnico di Torino)
مصطلحات موضوعية: Deep learning, Optic nerve, Optic nerve sheath, Segmentation, Transorbital ultrasound, Ultrasound
الوصف: Objective: Characterization of the optic nerve through measurement of optic nerve diameter (OND) and optic nerve sheath diameter (ONSD) using transorbital sonography (TOS) has proven to be a useful tool for the evaluation of intracranial pressure (ICP) and multiple neurological conditions. We describe a deep learning-based system for automatic characterization of the optic nerve from B-mode TOS images by automatic measurement of the OND and ONSD. In addition, we determine how the signal-to-noise ratio in two different areas of the image influences system performance. Methods: A UNet was trained as the segmentation model. The training was performed on a multidevice, multicenter data set of 464 TOS images from 110 subjects. Fivefold cross-validation was performed, and the training process was repeated eight times. The final prediction was made as an ensemble of the predictions of the eight single models. Automatic OND and ONSD measurements were compared with the manual measurements taken by an expert with a graphical user interface that mimics a clinical setting. Results: A Dice score of 0.719 ± 0.139 was obtained on the whole data set merging the test folds. Pearson's correlation was 0.69 for both OND and ONSD parameters. The signal-to-noise ratio was found to influence segmentation performance, but no clear correlation with diameter measurement performance was determined. Conclusion: The developed system has a good correlation with manual measurements, proving that it is feasible to create a model capable of automatically analyzing TOS images from multiple devices. The promising results encourage further definition of a standard protocol for the automatization of the OND and ONSD measurement process using deep learning-based methods. The image data and the manual measurements used in this work will be available at 10.17632/kw8gvp8m8x.1.
نوع الوثيقة: article in journal/newspaper
وصف الملف: STAMPA
اللغة: English
العلاقة: info:eu-repo/semantics/altIdentifier/wos/WOS:001051296500001; volume:49; issue:9; firstpage:2060; lastpage:2071; numberofpages:12; journal:ULTRASOUND IN MEDICINE AND BIOLOGY; https://hdl.handle.net/11583/2980124Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85162905326; https://www.sciencedirect.com/science/article/pii/S0301562923001692?via=ihubTest
DOI: 10.1016/j.ultrasmedbio.2023.05.011
الإتاحة: https://doi.org/10.1016/j.ultrasmedbio.2023.05.011Test
https://hdl.handle.net/11583/2980124Test
https://www.sciencedirect.com/science/article/pii/S0301562923001692?via=ihubTest
حقوق: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.8565DEB
قاعدة البيانات: BASE