The TRIBECA study : (TRI)fecta (B)ioprosthesis (E)valuation vs (C)arpentier Magna-Ease in (A)ortic position

التفاصيل البيبلوغرافية
العنوان: The TRIBECA study : (TRI)fecta (B)ioprosthesis (E)valuation vs (C)arpentier Magna-Ease in (A)ortic position
المؤلفون: A. Colli, G. Marchetto, S. Salizzoni, M. Rinaldi, L. Di Marco, D. Pacini, R. Di Bartolomeo, F. Nicolini, T. Gherli, M. Agrifoglio, V. Borghetti, G. Khoury, M. De Paolis, G. Zoffoli, D. Mangino, M.J. Amorim, E. Manzan, F. Zucchetta, S. Balduzzi, G. Gerosa
المساهمون: A. Colli, G. Marchetto, S. Salizzoni, M. Rinaldi, L. Di Marco, D. Pacini, R. Di Bartolomeo, F. Nicolini, T. Gherli, M. Agrifoglio, V. Borghetti, G. Khoury, M. De Paoli, G. Zoffoli, D. Mangino, M.J. Amorim, E. Manzan, F. Zucchetta, S. Balduzzi, G. Gerosa
بيانات النشر: Oxford University Press
سنة النشر: 2016
المجموعة: The University of Milan: Archivio Istituzionale della Ricerca (AIR)
مصطلحات موضوعية: Aortic valve replacement, Bioprosthesi, Magna Ease, Patient–prosthesis mismatch, Tissue valve, Trifecta, Settore MED/23 - Chirurgia Cardiaca
الوصف: OBJECTIVE: To determine whether the Trifecta bioprosthetic aortic valve produces postoperative haemodynamic results comparable with or better than those of the Magna Ease aortic valve bioprosthesis. METHODS: We retrospectively reviewed the medical records of patients who had undergone aortic valve replacement with Trifecta or Magna Ease prostheses at eight European institutions between January 2011 and May 2013, and analysed early postoperative haemodynamic performance by means of echocardiography. RESULTS: A total of 791 patients underwent aortic valve replacement (469 Magna Ease, 322 Trifecta). Haemodynamic variables were evaluated on discharge and during the follow-up (minimum 6 months, maximum 12 months). The mean gradient and the indexed effective orifice area (IEOA) were as follows: 10 mmHg [interquartile range (IQR): 8-13] and 1.10 cm2/m2 (IQR: 0.95-1.27) for Trifecta; 16 mmHg (IQR: 11-22) and 0.96 cm2/m2 (IQR: 0.77-1.13) for Magna Ease (P < 0.001). These significant differences were maintained across all valve sizes. Similar statistically significant differences were found when patients were matched and/or stratified for preoperative characteristics: body-surface area, ejection fraction, mean gradients and valve size. Severe prosthesis-patient mismatch (IEOA: <0.65 cm2/m2) was detected in 2 patients (0.6%) with Trifecta and 40 patients (8.5%) with Magna Ease (P < 0.001). CONCLUSIONS: The haemodynamic performance of the Trifecta bioprosthesis was superior to that of the Magna Ease valve across all conventional prosthesis sizes, with almost no incidence of severe patient-prosthesis mismatch. The long-term follow-up is needed to determine whether these significant haemodynamic differences will persist, and influence clinical outcomes.
نوع الوثيقة: article in journal/newspaper
اللغة: English
العلاقة: info:eu-repo/semantics/altIdentifier/pmid/25769464; info:eu-repo/semantics/altIdentifier/wos/WOS:000371819300023; volume:49; issue:2; firstpage:478; lastpage:485; numberofpages:8; journal:EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY; http://hdl.handle.net/2434/273354Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84959866887
DOI: 10.1093/ejcts/ezv070
الإتاحة: https://doi.org/10.1093/ejcts/ezv070Test
http://hdl.handle.net/2434/273354Test
حقوق: info:eu-repo/semantics/closedAccess
رقم الانضمام: edsbas.80B3F98C
قاعدة البيانات: BASE