Home Use of an Artificial Beta Cell in Type 1 Diabetes.

التفاصيل البيبلوغرافية
العنوان: Home Use of an Artificial Beta Cell in Type 1 Diabetes.
المؤلفون: Thabit, H, Tauschmann, M, Allen, JM, Leelarathna, L, Hartnell, S, Wilinska, ME, Acerini, CL, Dellweg, S, Benesch, C, Heinemann, L, Mader, JK, Holzer, M, Kojzar, H, Exall, J, Yong, J, Pichierri, J, Barnard, KD, Kollman, C, Cheng, P, Hindmarsh, PC, Campbell, FM, Arnolds, S, Pieber, TR, Evans, ML, Dunger, DB, Hovorka, R
بيانات النشر: Massachusetts Medical Society
//dx.doi.org/10.1056/nejmoa1509351
N Engl J Med
سنة النشر: 2015
المجموعة: Apollo - University of Cambridge Repository
مصطلحات موضوعية: Adolescent, Adult, Algorithms, Child, Cross-Over Studies, Diabetes Mellitus, Type 1, Equipment Design, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Infusion Pumps, Implantable, Insulin, Insulin Infusion Systems, Male, Middle Aged
الوصف: BACKGROUND: The feasibility, safety, and efficacy of prolonged use of an artificial beta cell (closed-loop insulin-delivery system) in the home setting have not been established. METHODS: In two multicenter, crossover, randomized, controlled studies conducted under free-living home conditions, we compared closed-loop insulin delivery with sensor-augmented pump therapy in 58 patients with type 1 diabetes. The closed-loop system was used day and night by 33 adults and overnight by 25 children and adolescents. Participants used the closed-loop system for a 12-week period and sensor-augmented pump therapy (control) for a similar period. The primary end point was the proportion of time that the glucose level was between 70 mg and 180 mg per deciliter for adults and between 70 mg and 145 mg per deciliter for children and adolescents. RESULTS: Among adults, the proportion of time that the glucose level was in the target range was 11.0 percentage points (95% confidence interval [CI], 8.1 to 13.8) greater with the use of the closed-loop system day and night than with control therapy (P<0.001). The mean glucose level was lower during the closed-loop phase than during the control phase (difference, -11 mg per deciliter; 95% CI, -17 to -6; P<0.001), as were the area under the curve for the period when the glucose level was less than 63 mg per deciliter (39% lower; 95% CI, 24 to 51; P<0.001) and the mean glycated hemoglobin level (difference, -0.3%; 95% CI, -0.5 to -0.1; P=0.002). Among children and adolescents, the proportion of time with the nighttime glucose level in the target range was higher during the closed-loop phase than during the control phase (by 24.7 percentage points; 95% CI, 20.6 to 28.7; P<0.001), and the mean nighttime glucose level was lower (difference, -29 mg per deciliter; 95% CI, -39 to -20; P<0.001). The area under the curve for the period in which the day-and-night glucose levels were less than 63 mg per deciliter was lower by 42% (95% CI, 4 to 65; P=0.03). Three severe hypoglycemic ...
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
العلاقة: https://www.repository.cam.ac.uk/handle/1810/251051Test
الإتاحة: https://www.repository.cam.ac.uk/handle/1810/251051Test
رقم الانضمام: edsbas.6A49460A
قاعدة البيانات: BASE