دورية أكاديمية

Platelet volume indices and von Willebrand factor levels in blood exposed to polymer- or heparin-coated membrane oxygenators

التفاصيل البيبلوغرافية
العنوان: Platelet volume indices and von Willebrand factor levels in blood exposed to polymer- or heparin-coated membrane oxygenators
المؤلفون: Tagaya, Masashi, Okano, Shinya, Murataka, Takuo, Handa, Hiroki, Ichikawa, Shunsuke, Takahashi, Shunsuke
المساهمون: policy-based medical services foundation
المصدر: The International Journal of Artificial Organs ; volume 47, issue 3, page 198-204 ; ISSN 0391-3988 1724-6040
بيانات النشر: SAGE Publications
سنة النشر: 2024
مصطلحات موضوعية: Biomedical Engineering, Biomaterials, General Medicine, Medicine (miscellaneous), Bioengineering
الوصف: Introduction: To understand the behavior of platelet volume indices and the von Willebrand factor (VWF), in vitro experiments using whole human blood were performed with extracorporeal circulation (ECC) circuits, including membrane oxygenators coated with acrylate copolymer (ACP) or immobilized heparin (IHP). Methods: Heparinized blood was circulated through two distinct experimental circuits: an ACP-coated reservoir and tubes, as well as membranes coated with either ACP or IHP (comprising five pieces of each type). The platelet distribution width, mean platelet volume (MPV), platelet large cell ratio (P-LCR), VWF quantity (VWFQ), and VWF activity (VWFA) were measured at 0, 8, 16, 24, and 32 h in each experiment. A two-way analysis of variance (ANOVA) was performed to determine whether the coating type or circulation duration affected the transition of each measurement. Results: Two-way ANOVA indicated that the transitions of MPV, P-LCR, and VWFA were significantly affected by the circulation duration ( p = 0.030, 0.001, and <0.001, respectively) and that the transitions of VWFQ and VWFA were significantly affected by the coating type ( p = 0.022 and 0.006, respectively). Factor interactions between the coating type and circulation duration were not observed for each transition ( p > 0.05). Conclusions: Our findings suggest that P-LCR is a good index for platelet activation in blood-circulating ECC and that VWFA and VWFQ are significantly attenuated in blood-circulating ECC with ACP-coated membranes, indicating the advantage of IHP coating regarding platelet activation.
نوع الوثيقة: article in journal/newspaper
اللغة: English
DOI: 10.1177/03913988231223360
الإتاحة: https://doi.org/10.1177/03913988231223360Test
حقوق: https://journals.sagepub.com/page/policies/text-and-data-mining-licenseTest
رقم الانضمام: edsbas.4D1FAAF7
قاعدة البيانات: BASE