دورية أكاديمية

In-Pile Qualification of the Fast-Neutron-Detection-System

التفاصيل البيبلوغرافية
العنوان: In-Pile Qualification of the Fast-Neutron-Detection-System
المؤلفون: Fourmentel D., Villard J-F., Destouches C., Geslot B., Vermeeren L., Schyns M.
المصدر: EPJ Web of Conferences, Vol 170, p 04025 (2018)
بيانات النشر: EDP Sciences
سنة النشر: 2018
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: Nuclear Measurements, Fission Chamber, Reactor Instrumentation, Physics, QC1-999
الوصف: In order to improve measurement techniques for neutron flux assessment, a unique system for online measurement of fast neutron flux has been developed and recently qualified in-pile by the French Alternative Energies and Atomic Energy Commission (CEA) in cooperation with the Belgian Nuclear Research Centre (SCK•ECEN). The Fast-Neutron-Detection-System (FNDS) has been designed to monitor accurately high-energy neutrons flux (E > 1 MeV) in typical Material Testing Reactor conditions, where overall neutron flux level can be as high as 1015 n.cm-2.s-1 and is generally dominated by thermal neutrons. Moreover, the neutron flux is coupled with a high gamma flux of typically a few 1015 γ.cm-2.s-1, which can be highly disturbing for the online measurement of neutron fluxes. The patented FNDS system is based on two detectors, including a miniature fission chamber with a special fissile material presenting an energy threshold near 1 MeV, which can be 242Pu for MTR conditions. Fission chambers are operated in Campbelling mode for an efficient gamma rejection. FNDS also includes a specific software that processes measurements to compensate online the fissile material depletion and to adjust the sensitivity of the detectors, in order to produce a precise evaluation of both thermal and fast neutron flux even after long term irradiation. FNDS has been validated through a two-step experimental program. A first set of tests was performed at BR2 reactor operated by SCK•CEN in Belgium. Then a second test was recently completed at ISIS reactor operated by CEA in France. FNDS proved its ability to measure online the fast neutron flux with an overall accuracy better than 5%.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 2100-014X
العلاقة: https://doi.org/10.1051/epjconf/201817004025Test; https://doaj.org/toc/2100-014XTest; https://doaj.org/article/f38410be668c435f883d9a59fc6c90f2Test
DOI: 10.1051/epjconf/201817004025
الإتاحة: https://doi.org/10.1051/epjconf/201817004025Test
https://doaj.org/article/f38410be668c435f883d9a59fc6c90f2Test
رقم الانضمام: edsbas.4866A021
قاعدة البيانات: BASE
الوصف
تدمد:2100014X
DOI:10.1051/epjconf/201817004025