Beam-shaping extended depth of focus intraocular lens: optical assessment with corneas of increasing spherical aberration

التفاصيل البيبلوغرافية
العنوان: Beam-shaping extended depth of focus intraocular lens: optical assessment with corneas of increasing spherical aberration
المؤلفون: Madrid Costa, David, Fernández-Vega Cueto, Luis, Azor Morón, Juan Antonio, Vega Lerín, Fidel, Millán Garcia-Varela, M. Sagrario, Alfonso, José F.
المساهمون: Universitat Politècnica de Catalunya. Doctorat en Enginyeria Òptica, Universitat Politècnica de Catalunya. Departament d'Òptica i Optometria, Universitat Politècnica de Catalunya. GOAPI - Grup d'Òptica Aplicada i Processament d'Imatge
سنة النشر: 2023
المجموعة: Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledge
مصطلحات موضوعية: Àrees temàtiques de la UPC::Ciències de la visió::Instruments òptics i optomètrics, Intraocular lenses, Optical instruments, Lents intraoculars, Òptica--Aparells i instruments
الوصف: PURPOSE:To assess the optical quality and halo formation of a beam-shaping extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity; Alcon Laboratories, Inc) with corneas of long-range spherical aberration (SA) such as those resulting from myopic laser ablations. METHODS:The optical quality of the EDOF IOL and a reference monofocal IOL was evaluated with three corneas (A, B, and C, with SA =+0.135, +0.290, +0.540 µm, respectively, for a 5.15-mm pupil at the IOL plane). The through-focus modulation transfer function area (MTFa) curves were obtained between -5.00 and +2.00 diopters (D) defocus range. The halo was also assessed with the three corneas. RESULTS:Through-focus MTFa curves for a 4.5-mm IOL pupil showed a slight decrease in the maximum MTFa value provided by the EDOF IOL compared to the monofocal IOL in the three corneal situations (A: 45.9 vs 38.6 units; B: 41.1 vs 33.1 units, and C: 26.9 vs 23.8 units). For the 3.0-mm pupil, the EDOF IOL also had lower maximum MTFa than the monofocal IOL; however, the depth-of-focus increased to -2.20 D. With corneas A and B, the halo induced was of low energy with both IOLs. With cornea C, the EDOF IOL created a much larger and intense halo. CONCLUSIONS:The EDOF IOL provided a good distance optical performance and an extended range of focus of approximately 2.00 D, with a halo of low intensity when evaluated with a corneal SA similar to the one induced by a low to moderate myopic ablation. With a high myopic ablation, the halo induced would be of considerable size and energy. ; Postprint (author's final draft)
نوع الوثيقة: article in journal/newspaper
وصف الملف: 8 p.; application/pdf
اللغة: English
تدمد: 1081-597X
العلاقة: Madrid-Costa, D. [et al.]. Beam-shaping extended depth of focus intraocular lens: optical assessment with corneas of increasing spherical aberration. "Journal of refractive surgery", Febrer 2023, vol. 39, núm. 2, p. 95-102.; http://hdl.handle.net/2117/390606Test
DOI: 10.3928/1081597X-20221215-02
الإتاحة: https://doi.org/10.3928/1081597X-20221215-02Test
http://hdl.handle.net/2117/390606Test
حقوق: Open Access
رقم الانضمام: edsbas.34284AB8