العنوان: Navigated percutaneous screw fixation of the pelvis with o-arm 2: Two years’ experience
المؤلفون: Ciolli G., Caviglia D., Vitiello C., Lucchesi S., Pinelli C., De Mauro D., Smakaj A., Rovere G., Meccariello L., Camarda L., Mac-Cauro G., Liuzza F.
المساهمون: Ciolli G., Caviglia D., Vitiello C., Lucchesi S., Pinelli C., De Mauro D., Smakaj A., Rovere G., Meccariello L., Camarda L., Mac-Cauro G., Liuzza F.
بيانات النشر: Medical Association of Zenica-Doboj Canton
BA
سنة النشر: 2021
المجموعة: IRIS Università degli Studi di Palermo
مصطلحات موضوعية: 3D-fluoroscopic navigation, Fragility fracture of pelvis, Iliosacral fixation, O-arm Stealth Station S8, Pelvic ring fractures
الوصف: Aim To evaluate the case series of the patients operated with percutaneous fixation by the navigation system based on 3D fluo-roscopic images, to assess the precision of a surgical implant and functional outcome of patients. Methods A retrospective study of pelvic ring fractures in a 2-year period included those treated with the use of the O-Arm 2 in com-bination with the Stealth Station 8. Pelvic fractures were classifi-ed according to the Tile and the Young-Burgess classification. All patients were examined before surgery, with X-rays and CT scans, and three days after surgery with additional CT scan. The positioning of the screws was evaluated according to the Smith score, the outcome with the SF-36. Results Among 24 patients 18 were with B and six with C type fracture according to Tile, while eight were with APC, 10 LC, and six with VS type according to Young-Burgess classification. All patients were treated in the supine position, except two. A total of 41 iliosacral or transsacral screws and five anterior pelvic ring screws were implanted. The medium surgical time per screw was 41 minutes. There was a perfect correspondence of screw scores value from post-operative CT and intraoperative fluoroscopy. The mean screw score value was 0.92. There were no cases of poor positioning. The median follow-up was 17.5 months. The patients were satisfied with their health condition on SF-36. Conclusion The use of the O-arm guarantees great precision in the positioning of the screws and reduced surgical times with excellent clinical results in patients.
نوع الوثيقة: article in journal/newspaper
اللغة: English
العلاقة: info:eu-repo/semantics/altIdentifier/pmid/33480224; volume:18; issue:1; firstpage:1; lastpage:7; numberofpages:7; journal:MEDICINSKI GLASNIK; http://hdl.handle.net/10447/480568Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85099959319
DOI: 10.17392/1326-21