Fast field echo resembling CT using restricted echo-spacing (FRACTURE) MR sequence can provide craniocervical region images comparable to a CT in dogs

التفاصيل البيبلوغرافية
العنوان: Fast field echo resembling CT using restricted echo-spacing (FRACTURE) MR sequence can provide craniocervical region images comparable to a CT in dogs
المؤلفون: Lee, Dongjae, Kim, Eunjee, Woo, Hyeonjae, Jeon, Chang-Yeop, Yoon, Junghee, Choi, Jihye
المساهمون: National Research Foundation
المصدر: Frontiers in Bioengineering and Biotechnology ; volume 12 ; ISSN 2296-4185
بيانات النشر: Frontiers Media SA
سنة النشر: 2024
المجموعة: Frontiers (Publisher - via CrossRef)
مصطلحات موضوعية: Biomedical Engineering, Histology, Bioengineering, Biotechnology
الوصف: Magnetic resonance imaging (MRI) is essential for evaluating cerebellar compression in patients with craniocervical junction abnormalities (CJA). However, it is limited in depicting cortical bone because of its short T2 relaxation times, low proton density, and organized structure. Fast field echo resembling a computed tomography (CT) scan using restricted echo-spacing (FRACTURE) MRI, is a new technique that offers CT-like bone contrast without radiation. This study aimed to assess the feasibility of using FRACTURE MRI for craniocervical junction (CCJ) assessment compared with CT and conventional MRI, potentially reducing the need for multiple scans and radiation exposure, and simplifying procedures in veterinary medicine. CT and MRI of the CCJ were obtained from five healthy beagles. MRI was performed using three-dimensional (3D) T1-weighted, T2-weighted, proton density-weighted (PDW), single echo-FRACTURE (sFRACTURE), and multiple echo-FRACTURE (mFRACTURE) sequences. For qualitative assessment, cortical delineation, trabecular bone visibility, joint space visibility, vertebral canal definition, overall quality, and artifacts were evaluated for each sequence. The geometrical accuracy, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were quantified. Both sFRACTURE and CT images provided significantly higher scores for cortical delineation and trabecular bone visibility than conventional MRI. Joint space visibility and vertebral canal definition were similar to those observed on CT images, regardless of the MR sequence. In the quantitative assessment, the distances measured on T2-weighted images differed significantly from those measured on CT. There were no significant differences between the distances taken using T1-weighted, PD-weighted, sFRACTURE, mFRACTURE and those taken using CT. T1-weighted and sFRACTURE had a higher SNR for trabecular bone than CT. The CNR between the cortical bone and muscle was high on CT and FRACTURE images. However, the CNR between the cortical and trabecular bones was ...
نوع الوثيقة: article in journal/newspaper
اللغة: unknown
DOI: 10.3389/fbioe.2024.1297675
DOI: 10.3389/fbioe.2024.1297675/full
الإتاحة: https://doi.org/10.3389/fbioe.2024.1297675Test
حقوق: https://creativecommons.org/licenses/by/4.0Test/