دورية أكاديمية

The test−retest reproducibility of the multiple array probe Leiden in men with lower urinary tract symptoms

التفاصيل البيبلوغرافية
العنوان: The test−retest reproducibility of the multiple array probe Leiden in men with lower urinary tract symptoms
المؤلفون: Beverini, Martina, Goes, Selma, Witte, Lambertus P.W., van Koeveringe, Gommert A., van der Laan, Nienke, Knol-de Vries, Grietje E., Blanker, Marco H.
المصدر: Beverini , M , Goes , S , Witte , L P W , van Koeveringe , G A , van der Laan , N , Knol-de Vries , G E & Blanker , M H 2023 , ' The test−retest reproducibility of the multiple array probe Leiden in men with lower urinary tract symptoms ' , Neurourology and urodynamics , vol. 42 , no. 4 , pp. 845-855 . https://doi.org/10.1002/nau.25157Test
سنة النشر: 2023
المجموعة: University of Groningen research database
مصطلحات موضوعية: electromyography, male LUTS, pelvic floor muscles
الوصف: Background: We aimed to study the test–retest reliability of the Multiple Array Probe Leiden (MAPLe), a multiple electrode probe designed to acquire and discriminate electromyography signals in the pelvic floor muscles, in men with lower urinary tract symptoms (LUTS). Methods: Adult male patients with LUTS with sufficient knowledge of Dutch language, but without complications (e.g., urinary tract infection), or previous urologic cancer and/or urologic surgery were enrolled. In the initial study, next to physical examination and uroflowmetry, all men underwent MAPLe assessment at baseline and after 6 weeks. Second, participants were reinvited for a new assessment using a stricter protocol. A time interval of 2 h (M2) and 1 week (M3) after baseline (M1) allowed the calculation of the intraday agreement (M1 vs. M2), and the interday agreement (M1 vs. M3) for all 13 MAPLe variables. Results: The outcomes of the initial study in 21 men suggested a poor test−retest reliability. The second study in 23 men showed a good test−retest reliability with intraclass correlations ranging from 0.61 (0.12−0.86) to 0.91 (0.81−0.96). The agreement was generally higher for the intraday determinations than for the interday determinations. Conclusions: This study revealed a good test−retest reliability of the MAPLe device in men with LUTS, when using a strict protocol. With a less strict protocol, the test−retest reliability of MAPLe was poor in this sample. To make valid interpretations of this device in a clinical or research setting, a strict protocol is needed.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
العلاقة: https://research.rug.nl/en/publications/561e1fef-2b56-4d38-bb57-ad879778a2f7Test
DOI: 10.1002/nau.25157
الإتاحة: https://doi.org/10.1002/nau.25157Test
https://hdl.handle.net/11370/561e1fef-2b56-4d38-bb57-ad879778a2f7Test
https://research.rug.nl/en/publications/561e1fef-2b56-4d38-bb57-ad879778a2f7Test
https://pure.rug.nl/ws/files/658948877/Neurourology_and_Urodynamics_2023_Beverini_The_test_retest_reproducibility_of_the_multiple_array_probe_Leiden_in_men.pdfTest
حقوق: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.1C46C2B
قاعدة البيانات: BASE