دورية أكاديمية

Structured reporting of computed tomography in the staging of colon cancer: a Delphi consensus proposal

التفاصيل البيبلوغرافية
العنوان: Structured reporting of computed tomography in the staging of colon cancer: a Delphi consensus proposal
المؤلفون: Granata V., Faggioni L., Grassi R., Fusco R., Reginelli A., Rega D., Maggialetti N., Buccicardi D., Frittoli B., Rengo M., Bortolotto C., Prost R., Lacasella G. V., Montella M., Ciaghi E., Bellifemine F., De Muzio F., Grazzini G., De Filippo M., Cappabianca S., Laghi A., Brunese L., Neri E., Miele V., Coppola F.
المساهمون: Granata, V., Faggioni, L., Grassi, R., Fusco, R., Reginelli, A., Rega, D., Maggialetti, N., Buccicardi, D., Frittoli, B., Rengo, M., Bortolotto, C., Prost, R., Lacasella, G. V., Montella, M., Ciaghi, E., Bellifemine, F., De Muzio, F., Grazzini, G., De Filippo, M., Cappabianca, S., Laghi, A., Brunese, L., Neri, E., Miele, V., Coppola, F.
سنة النشر: 2022
المجموعة: ARPI - Archivio della Ricerca dell'Università di Pisa
مصطلحات موضوعية: Colon cancer, Computed tomography, Radiology report, Structured report, Colon, Colonic Neoplasm, Consensu, Human, Neoplasm Staging, Research Report, Tomography, X-Ray Computed, Delphi Technique, Radiologists
الوصف: Background: Structured reporting (SR) in radiology is becoming increasingly necessary and has been recognized recently by major scientific societies. This study aims to build structured CT-based reports in colon cancer during the staging phase in order to improve communication between the radiologist, members of multidisciplinary teams and patients. Materials and methods: A panel of expert radiologists, members of the Italian Society of Medical and Interventional Radiology, was established. A modified Delphi process was used to develop the SR and to assess a level of agreement for all report sections. Cronbach’s alpha (Cα) correlation coefficient was used to assess internal consistency for each section and to measure quality analysis according to the average inter-item correlation. Results: The final SR version was built by including n = 18 items in the “Patient Clinical Data” section, n = 7 items in the “Clinical Evaluation” section, n = 9 items in the “Imaging Protocol” section and n = 29 items in the “Report” section. Overall, 63 items were included in the final version of the SR. Both in the first and second round, all sections received a higher than good rating: a mean value of 4.6 and range 3.6–4.9 in the first round; a mean value of 5.0 and range 4.9–5 in the second round. In the first round, Cronbach’s alpha (Cα) correlation coefficient was a questionable 0.61. In the first round, the overall mean score of the experts and the sum of scores for the structured report were 4.6 (range 1–5) and 1111 (mean value 74.07, STD 4.85), respectively. In the second round, Cronbach’s alpha (Cα) correlation coefficient was an acceptable 0.70. In the second round, the overall mean score of the experts and the sum of score for structured report were 4.9 (range 4–5) and 1108 (mean value 79.14, STD 1.83), respectively. The overall mean score obtained by the experts in the second round was higher than the overall mean score of the first round, with a lower standard deviation value to underline greater agreement among the ...
نوع الوثيقة: article in journal/newspaper
وصف الملف: STAMPA
اللغة: English
العلاقة: info:eu-repo/semantics/altIdentifier/pmid/34741722; info:eu-repo/semantics/altIdentifier/wos/WOS:000714993100001; volume:127; issue:1; firstpage:21; lastpage:29; numberofpages:9; journal:LA RADIOLOGIA MEDICA; https://hdl.handle.net/11568/1130772Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85118553899
DOI: 10.1007/s11547-021-01418-9
الإتاحة: https://doi.org/10.1007/s11547-021-01418-9Test
https://hdl.handle.net/11568/1130772Test
حقوق: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.17AA7E93
قاعدة البيانات: BASE