Variation of the relative biological effectiveness with fractionation in proton therapy: analysis of prostate cancer response

التفاصيل البيبلوغرافية
العنوان: Variation of the relative biological effectiveness with fractionation in proton therapy: analysis of prostate cancer response
المؤلفون: Pardo-Montero, Juan, Pombar, Miguel, Gómez-Caamaño, Antonio, Giordanengo, Simona, González-Crespo, Isabel
سنة النشر: 2023
المجموعة: Physics (Other)
مصطلحات موضوعية: Physics - Medical Physics
الوصف: Purpose: To present a methodology to analyze the variation of RBE with fractionation from clinical data of tumor control probability (TCP) and to apply it to study the response of prostate cancer to proton therapy. M&M: We analyzed the dependence of the RBE on the dose per fraction by using the LQ model and the Poisson TCP formalism. Clinical TCPs for prostate cancer treated with photon and proton therapy for conventional fractionation (2 Gy(RBE)x37 fractions), moderate hypofractionation (3 Gy(RBE)x20 fractions) and hypofractionation (7.25 Gy(RBE)x5 fractions) were obtained from the literature and analyzed. Results: The theoretical analysis showed three distinct regions with RBE monotonically decreasing, increasing or staying constant with the dose per fraction, depending on the change of ({\alpha}, \{beta}) values between photon and proton irradiation (the equilibrium point being at({\alpha}_p/\{beta}_p)=({\alpha}_X/\{beta}_X)({\alpha}_X/{\alpha}_p)). An analysis of the clinical data showed RBE values that decline with increasing dose per fraction: for low risk RBE=1.124, 1.119, and 1.102 for 1.82 Gy, 2.73 Gy and 6.59 Gy per fraction (physical proton doses), respectively; for intermediate risk RBE=1.119, and 1.102 for 1.82 Gy, and 6.59 Gy per fraction (physical proton doses), respectively. These values are nonetheless very close to the nominal 1.1 value. Conclusions: We presented a methodology to analyze the RBE for different fractionations, and we used it to study clinical data for prostate cancer. The analysis shows a monotonically decreasing RBE with increasing dose per fraction, which is expected from the LQ formalism and the changes in ({\alpha}, \{beta}) between photon and proton irradiation. However, the calculations in this study have to be considered with care as they may be biased by limitations in the modeling and/or by the clinical data set used for the analysis.
Comment: Minor changes to match accepted manuscript; in press Medical Physics
نوع الوثيقة: Working Paper
DOI: 10.1002/mp.16783
الوصول الحر: http://arxiv.org/abs/2303.09485Test
رقم الانضمام: edsarx.2303.09485
قاعدة البيانات: arXiv