Validating a fully automated real-time PCR-based system for use in the molecular diagnostic analysis of colorectal carcinoma: a comparison with NGS and IHC

التفاصيل البيبلوغرافية
العنوان: Validating a fully automated real-time PCR-based system for use in the molecular diagnostic analysis of colorectal carcinoma: a comparison with NGS and IHC
المؤلفون: Richard Colling, Elizabeth J. Soilleux, Lai Mun Wang
المصدر: Journal of clinical pathology. 70(7)
سنة النشر: 2017
مصطلحات موضوعية: 0301 basic medicine, Neuroblastoma RAS viral oncogene homolog, Oncology, Proto-Oncogene Proteins B-raf, medicine.medical_specialty, Pathology, Colorectal cancer, Concordance, Point-of-Care Systems, medicine.disease_cause, Real-Time Polymerase Chain Reaction, Pathology and Forensic Medicine, GTP Phosphohydrolases, Proto-Oncogene Proteins p21(ras), 03 medical and health sciences, 0302 clinical medicine, Internal medicine, medicine, Humans, Digital polymerase chain reaction, neoplasms, Molecular pathology, business.industry, Membrane Proteins, General Medicine, Ion semiconductor sequencing, medicine.disease, Immunohistochemistry, digestive system diseases, 030104 developmental biology, Real-time polymerase chain reaction, 030220 oncology & carcinogenesis, Mutation, KRAS, business, Colorectal Neoplasms
الوصف: BackgroundMolecular testing is increasingly needed in colorectal carcinoma (CRC) and the current clinically relevant mutations are in BRAF, KRAS and NRAS. This study aimed to further validate a new alternative polymerase chain reaction (PCR) platform (Idylla, Biocartis) against existing next-generation sequencing (NGS) and immunohistochemistry (IHC) assays.Methods56 Idylla tests were performed on 43 CRC cases, in a total of 74 comparisons against an NGS panel (Ion Torrent) and the VE1 (anti-BRAF) antibody IHC. Discrepant cases were also compared with either conventional (Cobas) or droplet digital PCR (Bio-Rad).ResultsIdylla showed an overall concordance of 100% (95% CI 93% to 100%) with comparator molecular testing and indications were that Idylla is likely to be more sensitive than routine NGS. BRAF IHC showed 90% concordance with NGS (95% CI 70% to 97%).ConclusionsThis study validates Idylla in formalin-fixed, paraffin-embedded CRC tissue. BRAF IHC, however, is an unreliable substitute for molecular testing in CRC.
تدمد: 1472-4146
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f7bc37900ea1a83c16cbb45788f68054Test
https://pubmed.ncbi.nlm.nih.gov/28292978Test
حقوق: EMBARGO
رقم الانضمام: edsair.doi.dedup.....f7bc37900ea1a83c16cbb45788f68054
قاعدة البيانات: OpenAIRE