A practical gait feedback method based on wearable inertial sensors for a drop foot assistance device

التفاصيل البيبلوغرافية
العنوان: A practical gait feedback method based on wearable inertial sensors for a drop foot assistance device
المؤلفون: Uriel Martinez-Hernandez, Arjan Buis, Abbas A. Dehghani-Sanij, Lin Meng, Craig Childs
المصدر: Meng, L, Martinez Hernandez, U, Childs, C, Dehghani-Sanij, A A & Buis, A 2019, ' A practical gait feedback method based on wearable inertial sensors for a drop foot assistance device ', IEEE Sensors Journal, vol. 19, no. 24, 8822472, pp. 12235-12243 . https://doi.org/10.1109/JSEN.2019.2938764Test
سنة النشر: 2019
مصطلحات موضوعية: Motion analysis, Inertial frame of reference, Computer science, Kinematics, 01 natural sciences, Inertial measurement unit, TA164, medicine, Electrical and Electronic Engineering, Treadmill, Instrumentation, Simulation, Robotic control, Ankle angle, sensor data fusion, 010401 analytical chemistry, gait phase recognition, Inertial measurement units, gyroscopes and accelerometers, Gait, 0104 chemical sciences, ankle angle measurement, medicine.anatomical_structure, hierarchical structure, Gait analysis, gait analysis, Ankle
الوصف: To maximise the efficiency of gait interventions, gait phase and joint kinematics are important for closing the system loop of adaptive robotic control. However, few studies have applied an inertial sensor system including both gait phase detection and joint kinematic measurement. Many algorithms for joint measurement require careful alignment of the inertial measurement unit (IMU) to the body segment. In this paper, we propose a practical gait feedback method, which provides sufficient feedback without requiring precise alignment of the IMUs. The method incorporates a two-layer model to realise simultaneous gait stance and swing phase detection and ankle joint angle measurement. Recognition of gait phases is performed by a high-level probabilistic method using angular rate from the sensor attached to the shank while the ankle angle is calculated using a data fusion algorithm based on the complementary filter and sensor-to-segment calibration. The online performance of the algorithm was experimentally validated when 10 able-bodied participants walked on the treadmill with three different speeds. The outputs were compared to the ones measured by an optical motion analysis system. The results showed that the IMU-based algorithm achieved a good accuracy of the gait phase recognition (above 95%) with a short delay response below 20 ms and accurate angle measurements with root mean square errors below 3.5° compared to the optical reference. It demonstrates that our method can be used to provide gait feedback for the correction of drop foot.
وصف الملف: application/pdf
اللغة: English
تدمد: 1530-437X
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e151ad26c3f67f9e8cf8b6c7242f28b7Test
https://strathprints.strath.ac.uk/69886/1/Meng_etal_IEEESJ_2019_A_practical_gait_feedback_method_based_on_wearable_inertial.pdfTest
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....e151ad26c3f67f9e8cf8b6c7242f28b7
قاعدة البيانات: OpenAIRE