Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve

التفاصيل البيبلوغرافية
العنوان: Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve
المؤلفون: Federica Cosentino, Francesca Pasta, Giovanni Gentile, Michele Pilato, Caterina Gandolfo, Valentina Agnese, Diego Bellavia, Marzio Di Giuseppe, Stefano Cannata, Giuseppe Maria Raffa, Salvatore Pasta
المساهمون: Pasta S., Cannata S., Gentile G., Di Giuseppe M., Cosentino F., Pasta F., Agnese V., Bellavia D., Raffa G.M., Pilato M., Gandolfo C.
بيانات النشر: Springer, 2020.
سنة النشر: 2020
مصطلحات موضوعية: Male, Models, Anatomic, medicine.medical_treatment, 02 engineering and technology, 030218 nuclear medicine & medical imaging, 0302 clinical medicine, Bicuspid aortic valve, Bicuspid Aortic Valve Disease, Image Processing, Computer-Assisted, Cardiac skeleton, Precision Medicine, Aged, 80 and over, Cardiac cycle, Settore ING-IND/34 - Bioingegneria Industriale, Computer Science Applications, medicine.anatomical_structure, Surgery, Computer-Assisted, cardiovascular system, Cardiology, Female, medicine.symptom, medicine.medical_specialty, 0206 medical engineering, Finite Element Analysis, Biomedical Engineering, Diastole, Transcatheter Aortic Valve Replacement, 03 medical and health sciences, Fluid-solid interaction, Internal medicine, Preoperative Care, medicine, Deformity, Humans, In patient, Heart valve, Aged, Retrospective Studies, Transcatheter aortic valve implantation, business.industry, Stent, Computational Biology, Finite-element analysi, Aortic Valve Stenosis, medicine.disease, 020601 biomedical engineering, business, Tomography, X-Ray Computed, Echocardiography, Transesophageal
الوصف: Bicuspid aortic valve (BAV) anatomy has routinely been considered an exclusion in the setting of transcatheter aortic valve implantation (TAVI) because of the large dimension of the aortic annulus having a more calcified, bulky, and irregular shape. The study aims to develop a patient-specific computational framework to virtually simulate TAVI in stenotic BAV patients using the Edwards SAPIEN 3 valve (S3) and its improved version SAPIEN 3 Ultra and quantify stent frame deformity as well as the severity of paravalvular leakage (PVL). Specifically, the aortic root anatomy of n.9 BAV patients who underwent TAVI was reconstructed from pre-operative CT imaging. Crimping and deployment of S3 frame were performed and then followed by fluid-solid interaction analysis to simulate valve leaflet dynamics throughout the entire cardiac cycle. Modeling revealed that the S3 stent frame expanded well on BAV anatomy with an elliptical shape at the aortic annulus. Comparison of predicted S3 deformity as assessed by eccentricity and expansion indices demonstrated a good agreement with the measurement obtained from CT imaging. Blood particle flow analysis demonstrated a backward blood jet during diastole, whereas the predicted PVL flows corresponded well with those determined by transesophageal echocardiography. This study represents a further step towards the use of personalized simulations to virtually plan TAVI, aiming at improving not only the efficacy of the implantation but also the exploration of "off-label" applications as the TAVI in the setting of BAV patients. Graphical abstract Computational frameworks of TAVI in patients with stenotic bicuspid aortic valve.
اللغة: English
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d774cee0700f5aebec063212c7cb498cTest
http://hdl.handle.net/10447/398343Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....d774cee0700f5aebec063212c7cb498c
قاعدة البيانات: OpenAIRE