Diagnostic Value of Hounsfield Unit and Hematocrit Levels in Cerebral Vein Thrombosis in the Emergency Department

التفاصيل البيبلوغرافية
العنوان: Diagnostic Value of Hounsfield Unit and Hematocrit Levels in Cerebral Vein Thrombosis in the Emergency Department
المؤلفون: Mustafa Emin Canakci, Evvah Karakilic, Betul Tiryaki Bastug, Nurdan Acar, Engin Ozakin, Caglar Kuas, Atilla Özcan Özdemir
المصدر: The Journal of Emergency Medicine. 61:234-240
بيانات النشر: Elsevier BV, 2021.
سنة النشر: 2021
مصطلحات موضوعية: medicine.diagnostic_test, business.industry, Significant difference, Thrombosis, Retrospective cohort study, Cerebral vein thrombosis, Emergency department, Hematocrit, medicine.disease, Cerebral Veins, Sensitivity and Specificity, Hounsfield scale, Emergency Medicine, medicine, Humans, Hematocrit levels, Cerebral venous sinus thrombosis, Emergency Service, Hospital, Nuclear medicine, business, Retrospective Studies
الوصف: Unenhanced computed tomography (CT) is a frequently used imaging method in patients who are evaluated in the emergency department with suspected cerebral vein thrombosis (CVT).The aim of this study was to investigate the usefulness of the Hounsfield unit (HU) value determined by CT and its ratio to the patient's hematocrit (Htc) value in the diagnosis of cerebral vein thrombosis.This retrospective study evaluated 41 patients with acute cerebral venous sinus thrombosis and 41 age- and sex-matched control participants. Two experienced observers independently evaluated the CT scan and measured the attenuation of the dural sinuses.There was no significant difference in age, gender, hemoglobin, and Htc values between the two groups. The mean HU value was 75 ± 7 HU in the CVT group and 52 ± 6 HU in the control group (p0.001). The mean HU/Htc ratio was 1.9 ± 0.3 in the CVT group and 1.3 ± 0.1 in the control group (p0.001). The optimal threshold value for HU was determined as 66, and sensitivity at this value was 93%, and specificity was 98%. The optimal threshold value for HU/Htc was determined as 1.64, and the sensitivity at this value was 90% and the specificity was 100%.Hyperattenuation in the dural sinuses and the HU/Htc ratio in unenhanced brain CT scans have high diagnostic value in detecting CVT.
تدمد: 0736-4679
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c8913086efc4f4f3b67765c432723a86Test
https://doi.org/10.1016/j.jemermed.2021.07.016Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....c8913086efc4f4f3b67765c432723a86
قاعدة البيانات: OpenAIRE