The New Generation Immunochemical Test for Fecal Occult Blood (ColonView Quick Test) Shows a High Diagnostic Accuracy in Colorectal Cancer Detection

التفاصيل البيبلوغرافية
العنوان: The New Generation Immunochemical Test for Fecal Occult Blood (ColonView Quick Test) Shows a High Diagnostic Accuracy in Colorectal Cancer Detection
المؤلفون: Eskelinen M, Jannica Meklin, Denise Peixoto Guimarães, Kari Syrjänen, Tuomas Selander, Jenni Inkinen, Matti Eskelinen, Tapani Tiusanen
المصدر: Anticancer research. 41(10)
سنة النشر: 2021
مصطلحات موضوعية: Cancer Research, medicine.medical_specialty, Quick Test, Colorectal cancer, Diagnostic accuracy, Gastroenterology, Internal medicine, medicine, Humans, Early Detection of Cancer, Receiver operating characteristic, Crc screening, business.industry, Immunochemistry, Fecal occult blood, General Medicine, Colonoscopy, medicine.disease, Prognosis, Test (assessment), Oncology, ROC Curve, Fecal Immunochemical Test, Occult Blood, business, Colorectal Neoplasms
الوصف: Background/aim The present study compared the accuracy of visually analyzed (VA) and automatically analyzed (AA) ColonView (CV) quick test; a new-generation immunochemical test (FIT) for Hb and Hb/Hp (Biohit Oyj, Helsinki, Finland) in subjects participating in colorectal cancer (CRC) detection in Brazil. A traditional gFOBT test (HemoccultSENSA) was used as a reference. Patients and methods A cohort of 368 colonoscopy-referral patients were asked to collect 3 consecutive fecal samples, to be analysed by both assays (CV, SENSA). Results In receiver operating characteristic (ROC) analysis for the AA reading, the optimal cut-off value for CV Hb AA (test AA 3) was ≥117 and that for CV Hb/Hp AA (test AA 4) was ≥48. In the hierarchical summary receiver operating characteristic (HSROC) analysis for pooled accuracy of CV with AA and VA reading, the AUC values for i) VA and ii) AA were as follows: i) AUC=0.859 (95%CI=0.839-0.879), ii) AUC=0.931 (95%CI=0.920-0.942). The difference between these AUC values (Roccomp analysis) was statistically significant (p=0.0024). Conclusion The present study confirms the previous studies on the applicability of the ColonView quick test (a new-generation FIT) in CRC screening.
تدمد: 1791-7530
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7f4862e27dead1050549fa82f66a8a13Test
https://pubmed.ncbi.nlm.nih.gov/34593457Test
رقم الانضمام: edsair.doi.dedup.....7f4862e27dead1050549fa82f66a8a13
قاعدة البيانات: OpenAIRE