Long-term Durability of Coil Embolization for Unruptured Aneurysm after Introduction of the Neck-bridge Stent: Comparison between the Pre-stent Era and the Stent Era

التفاصيل البيبلوغرافية
العنوان: Long-term Durability of Coil Embolization for Unruptured Aneurysm after Introduction of the Neck-bridge Stent: Comparison between the Pre-stent Era and the Stent Era
المؤلفون: Hisayuki Hosoo, Masahiro Katsumata, Wataro Tsuruta, Eiichi Ishikawa, Yuji Matsumaru, Akira Matsumura, Daiichiro Ishigami
المصدر: Neurologia medico-chirurgica
بيانات النشر: The Japan Neurosurgical Society, 2021.
سنة النشر: 2021
مصطلحات موضوعية: medicine.medical_specialty, Long term durability, medicine.medical_treatment, Context (language use), coil embolization, neck-bridge stent, 030218 nuclear medicine & medical imaging, 03 medical and health sciences, 0302 clinical medicine, medicine, Humans, cardiovascular diseases, Retrospective Studies, Coil embolization, business.industry, Stent, Intracranial Aneurysm, equipment and supplies, Embolization, Therapeutic, Surgery, cerebral aneurysm, Treatment Outcome, surgical procedures, operative, Bridge (graph theory), Hemorrhagic complication, Original Article, Stents, Unruptured aneurysm, Neurology (clinical), business, 030217 neurology & neurosurgery
الوصف: More complex aneurysms can be treated by coil embolization with neck-bridge stent assistance. However, concerns about postprocedural ischemic or hemorrhagic complications remain. In this study, we assessed the long-term durability after introduction of neck-bridge stent in the context of coil embolization for unruptured aneurysm by comparing re-treatment and neurological events between the pre-stent and stent eras. Unruptured aneurysms treated by coil embolization between April 2005 and May 2018 were analyzed retrospectively. We divided cases into two groups: the pre-stent era and the stent era. The cumulative rate of re-treatment and neurological events were assessed and compared. During the period, 177 aneurysms were treated in the pre-stent era and 354 aneurysms were treated in the stent era. The median follow-up was 55 months. In the stent era, the dome/neck (D/N) ratio was significantly lower (P
وصف الملف: application/pdf
اللغة: English
تدمد: 0470-8105
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::781798cc183c1c22b290ee660df8be9dTest
https://tsukuba.repo.nii.ac.jp/records/2004797Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....781798cc183c1c22b290ee660df8be9d
قاعدة البيانات: OpenAIRE