Strain Transfer of Fiber Bragg Grating Sensor Externally Bonded to FRP Strip for Structural Monitoring after Reinforcement

التفاصيل البيبلوغرافية
العنوان: Strain Transfer of Fiber Bragg Grating Sensor Externally Bonded to FRP Strip for Structural Monitoring after Reinforcement
المؤلفون: Hyun-Do Yun, Gun-Cheol Lee, Jeong-Hun Park, Seongwon Hong, Soo-Yeon Seo, Kang Su Kim
المصدر: Materials
Volume 14
Issue 16
Materials, Vol 14, Iss 4382, p 4382 (2021)
بيانات النشر: Multidisciplinary Digital Publishing Institute, 2021.
سنة النشر: 2021
مصطلحات موضوعية: Technology, Optical fiber, Materials science, optical fiber sensor, adhesion length, Article, law.invention, fiber Bragg grating, epoxy resin, Fiber Bragg grating, law, General Materials Science, Composite material, Reinforcement, fiber-reinforced polymer strip, Tensile testing, Microscopy, QC120-168.85, sensing performance, QH201-278.5, Adhesion, Epoxy, Fibre-reinforced plastic, Engineering (General). Civil engineering (General), TK1-9971, monitoring, Descriptive and experimental mechanics, Fiber optic sensor, visual_art, visual_art.visual_art_medium, Electrical engineering. Electronics. Nuclear engineering, TA1-2040
الوصف: To date, a method of attaching a FRP (fiber-reinforced polymer) to concrete members with epoxy has been widely applied to increase the strength of the member. However, there are cases in which the adhesion of the epoxy deteriorates over time and the reinforcing effect of the FRP is gradually lost. Therefore, monitoring whether or not the reinforcing effect is properly maintained is needed in order to prevent a decrease in the structural performance of the member improved by FRP reinforcement. In this regard, this study examines FRP with OF (optical fiber) sensors to monitor the reinforcing effect of FRP in concrete structural members. In particular, this paper seeks to determine an appropriate adhesion length when FBG (fiber Bragg grating) based OF sensors are externally bonded to FRP strips with epoxy resin. To this end, a tensile test was carried out to evaluate the sensing performance according to the adhesion length. In addition, an analytical approach was performed and the result were compared with test result. The results of the experimental and analytical studies showed that the strain generated in the FRP is sufficiently transferred to the OF if the total adhesion length of it is 40 mm or more in consideration of the error in the epoxy thickness.
وصف الملف: application/pdf
اللغة: English
تدمد: 1996-1944
DOI: 10.3390/ma14164382
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::74055a9a7da72f262ac30ae9fc04c485Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....74055a9a7da72f262ac30ae9fc04c485
قاعدة البيانات: OpenAIRE
الوصف
تدمد:19961944
DOI:10.3390/ma14164382