Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles

التفاصيل البيبلوغرافية
العنوان: Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles
المؤلفون: A. Raulo, Giulio Ventura, Waldes Dusi, E. Perillo, S. Vitulli, Gianni Landini, Ariano Donati, Adriano Cola
المساهمون: Perillo, Eugenio, Cola, A., Donati, A., Dusi, W., Landini, G., Raulo, A., Ventura, G., Vitulli, S.
المصدر: 531 (2004): 125–133.
info:cnr-pdr/source/autori:Perillo E, Cola A, Donati A, Dusi W, Landini G, Raulo A, Ventura G, Vitulli S/titolo:Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles/doi:/rivista:/anno:2004/pagina_da:125/pagina_a:133/intervallo_pagine:125–133/volume:531
بيانات النشر: Elsevier BV:PO Box 211, 1000 AE Amsterdam Netherlands:011 31 20 4853757, 011 31 20 4853642, 011 31 20 4853641, EMAIL: nlinfo-f@elsevier.nl, INTERNET: http://www.elsevier.nlTest, Fax: 011 31 20 4853598, 2004.
سنة النشر: 2004
مصطلحات موضوعية: Physics, Nuclear and High Energy Physics, business.industry, Detector, Electron, Cathode, Particle detector, Anode, law.invention, Semiconductor detector, Optics, law, Electrode, business, Instrumentation, Beam (structure)
الوصف: A study of the spectroscopic response of a CdTe detector, 10 mm x 3 mm x 3 mm in size, equipped with a 10 mm x 3 mm full cathode and a 10 mm x 0.3 mm central strip anode placed between two parallel focusing strips spaced of about 0.050 mm from the collecting anode, was carried out. This configuration increases the intensity of the weighing field surrounding the anode strip, thus improving the collection of the electrons. The detector was irradiated through the cathode by a narrow photon beam (Co-57 source) at various impinging angles theta in the range 0-87degrees, theta being the angle between the photon beam axis and the normal to the cathode surface, aiming at obtaining better spectroscopic performance. The measurements were carried out with the long side of the beam spot (0.90 mm x 0.18 mm) oriented both transversal and parallel to the central strip anode. In this last case, significant improvements for some spectroscopic parameters were obtained; e.g. the peak-to-valley ratio of the 122-keV peak changes from 13.5 at 0degrees to 25.8 at 82degrees, i.e. an almost two times better value.
وصف الملف: STAMPA
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6f62d621bf3ef2d113c7a1f1f60ba4fbTest
http://hdl.handle.net/11588/108942Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....6f62d621bf3ef2d113c7a1f1f60ba4fb
قاعدة البيانات: OpenAIRE