Balloon pulmonary angioplasty relieves haemodynamic stress towards untreated-side pulmonary vasculature and improves its resistance in patients with chronic thromboembolic pulmonary hypertension

التفاصيل البيبلوغرافية
العنوان: Balloon pulmonary angioplasty relieves haemodynamic stress towards untreated-side pulmonary vasculature and improves its resistance in patients with chronic thromboembolic pulmonary hypertension
المؤلفون: Koshin Horimoto, Kazuya Hosokawa, Kohtaro Abe, Hiroyuki Tsutsui, Michinobu Nagao, Yuzo Yamasaki
المصدر: EuroIntervention. 13:2069-2076
بيانات النشر: Europa Digital & Publishing, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Male, endocrine system, medicine.medical_specialty, Hypertension, Pulmonary, medicine.medical_treatment, Hemodynamics, Pulmonary Artery, 030204 cardiovascular system & hematology, Balloon, 03 medical and health sciences, Postoperative Complications, 0302 clinical medicine, Angioplasty, Internal medicine, medicine.artery, medicine, Humans, Arterial Pressure, In patient, Aged, urogenital system, business.industry, Middle Aged, Treatment Outcome, medicine.anatomical_structure, Blood pressure, 030228 respiratory system, Chronic Disease, Pulmonary artery, Disease Progression, Vascular resistance, Cardiology, Female, Vascular Resistance, Chronic thromboembolic pulmonary hypertension, Pulmonary Embolism, Cardiology and Cardiovascular Medicine, business, Angioplasty, Balloon, hormones, hormone substitutes, and hormone antagonists
الوصف: AIMS Chronic thromboembolic pulmonary hypertension (CTEPH) is characterised by organised thrombotic obliteration of major vessels and small-vessel arteriopathy in the non-thrombosed vessels. The aim of this study was to investigate the impact of balloon pulmonary angioplasty (BPA) on the non-BPA-side pulmonary vasculature in patients with CTEPH. METHODS AND RESULTS This study explored the outcomes of 20 unilateral BPA sessions in 13 CTEPH patients. We measured the pulmonary vascular resistance (PVR), pulmonary artery (PA) flow in the BPA-side and non-BPA-side lungs, respectively, using phase contrast MRI and cardiac catheterisation. The interval from BPA to the follow-up evaluation was 92.8±52.0 days. A single session of BPA decreased mean PA pressure from 37.4±6.2 to 30.9±6.5 mmHg (p
تدمد: 1774-024X
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5bad1d18b6938492f93b1fa806f2eee8Test
https://doi.org/10.4244/eij-d-17-00888Test
رقم الانضمام: edsair.doi.dedup.....5bad1d18b6938492f93b1fa806f2eee8
قاعدة البيانات: OpenAIRE