A practical method to measure GFR in people with type 1 diabetes

التفاصيل البيبلوغرافية
العنوان: A practical method to measure GFR in people with type 1 diabetes
المؤلفون: Samuel L. Ellis, A Bouffard, Becky Jo Kerr, David M. Maahs, Laura Pyle, Kimberly K. McFann, Nhung Viet Nguyen, Peter L. Anderson, Lane R. Bushman, Franziska K. Bishop
المصدر: Journal of Diabetes and its Complications. 28:667-673
بيانات النشر: Elsevier BV, 2014.
سنة النشر: 2014
مصطلحات موضوعية: Adult, Blood Glucose, Male, medicine.medical_specialty, Diagnostic methods, Adolescent, Iohexol, Endocrinology, Diabetes and Metabolism, Urology, Renal function, Kidney Function Tests, urologic and male genital diseases, Young Adult, chemistry.chemical_compound, Endocrinology, Diabetes mellitus, Internal medicine, Internal Medicine, medicine, Humans, Diabetic Nephropathies, Dried blood, reproductive and urinary physiology, Type 1 diabetes, Creatinine, biology, urogenital system, business.industry, medicine.disease, female genital diseases and pregnancy complications, Diabetes Mellitus, Type 1, chemistry, Cystatin C, biology.protein, Female, Dried Blood Spot Testing, business, Glomerular Filtration Rate, Kidney disease
الوصف: Aims Improved early diagnostic methods are needed to identify risk for kidney disease in people with type 1 diabetes. We hypothesized that glomerular filtration rate (GFR) measured by iohexol clearance in dried blood spots (DBS) on filter paper would be comparable to plasma (gold-standard) and superior to estimated GFR (eGFR) and, second, that adjustment for ambient blood glucose would improve accuracy and precision of GFR measurement. Methods GFR was measured by iohexol clearance in plasma, DBS, and as estimated by the CKD-Epidemiology Collaboration equations in 15 adults with type 1 diabetes at two visits, one euglycemic and one hyperglycemic. Results GFR measured by DBS was more comparable and less biased than GFR cystatin C, serum creatinine, and both combined. GFR was higher during hyperglycemia. Correction for between visit glycemia statistically significantly reduced bias and mean squared error for GFR measured by DBS as compared to gold-standard during euglycemia. Conclusions Iohexol clearance measured with DBS performed better than eGFR methods. Correction for ambient blood glucose improved precision and accuracy of GFR measurement. This method is more convenient than the gold-standard GFR method and may improve screening and diagnostic capabilities in people with type 1 diabetes, especially when GFR is >60ml/min/1.73m 2 .
تدمد: 1056-8727
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2cfcd7dcb5088399012090474c4bdc97Test
https://doi.org/10.1016/j.jdiacomp.2014.06.001Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....2cfcd7dcb5088399012090474c4bdc97
قاعدة البيانات: OpenAIRE